22
+380 44 507 02 07
Fig. 8. Generation of the Event by Going Beyond Range.
2 - Going within/beyond range.
An event will be generated each time when actual value of
sensor readings crosses the limits of a configured range.
Example:
Lower threshold of input voltage is set to 5 V (5,000),
and the upper threshold is 10 V (10,000 mV). When actual
input voltage goes off the limits of a configured range, the
event is generated (Figure 9).
Fig. 9. Generation of the Event by Going Within/Beyond Range.
3 - Monitoring.
When this mode is selected, the data will be transmitted
continuously, and no events will be generated.
4 - Moni Going Within Range.
When a
Going Within Range
event is generated, actual value
from the sensor starts to be transmitted to the server in the
monitoring mode.
5 - Moni Going Beyond Range.