5.3

 

Software Version Checking 

Through ‘System->Overview‘, you will be able to check the software version you used. 
After  upgrading  the  software,  to  check  if  you  are  using  the  latest  version  of  software  via  ‘File 
System Version’. 

5.4

 

Restore Initial Setting 

Press  the  ‘Reset’  button  on  the  left  bottom  of  LCD  screen  and  hold  on  for  3  seconds,  red  led 
flashing  every  one  second/1S.  Release  ‘Reset’  button, 

the  server

  will  restore  the  initial

setting  and  restart automatically. 

Summary of Contents for AntMiner S4

Page 1: ...BITMAIN S4 Server Manual ...

Page 2: ... Overview 3 2 Connect to Server 3 3 Server Configuration 4 3 1 Pool Setting 4 3 2 Frequency Modification 5 4 Server Status 5 5 System Configuration and status 6 5 1 System Upgrading 6 5 2 Password Modification 6 5 3 Software Version Checking 7 5 4 Restore Initial Setting 7 ...

Page 3: ...lso status LEDS reset button and beep on the screen Casing size 3U Rack 432mm 442mm 133mm 2 Connect to Server Step 1 The default DHCP network protocol distributes IP addresses automatically After you have your server hooked up you will see the IP address on the LCD display Step 2 Connect your server to the PC with network cable Step 3 Enter server s IP address into your web browser then login in t...

Page 4: ...t up with three mining pools the priority decreases from first pool pool 1 to third pool pool 3 The pool with low priority will start to work only when the high priority pool breaks down 3 1 2 With Beeper ringing checked beeper will ring when the server stops mining otherwise it won t ring even if the server stops mining 3 1 3 With Stop running when temperature is over 80 checked the server will s...

Page 5: ...ed Settings E g Voltage 0720 means operating voltage of chip is 0 72V Voltage needs to be modified when adjusting the frequency 4 Server Status Click the status marked below you can check the operating status of your server ASIC ASIC number in the chain Frequency ASIC setting frequency Temp Temperature centigrade ASIC status o stands for OK x stands for error ...

Page 6: ...ck Flash image button it will remind if upgrading software start to download software after choosing upgrading software During the upgrade process you need to wait patiently and must keep power on otherwise the server should be shipped to factory to restore You will see bellow screenshot after upgrading successfully Choose Reboot button server will restart and run the new system Choose Go Back ser...

Page 7: ...ion you used After upgrading the software to check if you are using the latest version of software via File System Version 5 4 Restore Initial Setting Press the Reset button on the left bottom of LCD screen and hold on for 3 seconds red led flashing every one second 1S Release Reset button the server will restore the initial setting and restart automatically ...

Page 8: ...Page 8 8 S4 Server Manual Last updated 9 29 2014 Page 7 of 8 ...