S19 Pro+ Hydro Server Installation
- 7 -
1. Overview
1.2
Specifications
Detailed Characteristics
Value
Power Supply
Power supply AC input voltage,
Volt
(2-1)
342~418
Power supply AC Input Frequency Range,
Hz
47~63
Power supply AC Input current,
Amp
(2-2)
30
Hardware Configuration
Network connection mode
RJ45 Ethernet 10/100M
Server Size (Length*Width*Height, w/o
package),
mm
410*196*209
Server Size (Length*Width*Height, with package),
mm
570*316*430
Net weight,
kg
15.2
Gross weight,
kg
17.5
Environment Requirements
Operation temperature,
°C
(2-3)
0~40
Inlet water temperature,
°C
20-40
Water flow
L/min
8
±
10%
Water pressure bar
≤
3.5
Storage temperature,
°C
-20~70
Operation humidity(non-condensing),
RH
10~90%
Product Glance
Value
Version
Hydro
Model
j0-10
Crypto Algorithm/Coins
SHA256/BTC/BCH
Hashrate,
TH/s
198 ± 3%
191 ± 3%
184 ± 3%
177 ± 3%
170 ± 3%
Power on wall
@Tj65°C ,
Watt
(1-1)
5445 ± 5%
5253 ± 5%
5060 ± 5%
4868 ± 5%
4675 ± 5%
Power efficiency on
wall
@Tj65°C, J/TH
(1-1)
27.5 ± 5%
27.5 ± 5%
27.5 ± 5%
27.5 ± 5%
27.5 ± 5%