background image

12

Stain Removal

Do Not Delay! 

Failure to attend to an accident soon after it occurs 

may cause it to set and become permanent.

Before treating any stain, follow these pretreatment steps:

Blot up liquids with an absorbent cloth or paper towels. 
White materials are recommended because certain dyes 
may bleed and make the stain worse.

Gently scrape up semi-solids with a spoon or spatula. 
Do not use a knife or other utensil with sharp edges 
because it could damage the carpet or upholstery.

If the area has dried, remove the remaining semi-solids 
and residue with a sweeper or vacuum. 

Be sure to pre-test any spot removal solutions or chemicals 
on an inconspicuous area first. This is extremely 
important; different dyes and materials could be damaged 
or discoloured by a cleaning solution. If such a change 
should occur, try a different solution or call a professional. If 
cleaning on Berber Carpet gently run your machine over 
a hidden area. If no fuzzing occurs, continue cleaning in 
soiled area.

Use your BISSELL Deep Cleaner as a precleaner. With 
one of the tools attached to the Flex Hose, set the 
ReadyTools Dial to 

Tools/PreTreat

 and the Smart Mix 

Dial to the 

High Traffic

 setting. Spray the area with 

cleaning solution and allow the BISSELL Advanced Deep 
Cleaning Formula to penetrate for 3-5 minutes.

Once the precleaning is complete, use the attached tool 
to gently scrub the stain with back and forth strokes.

Allow to dry. Some difficult stains may require a second 
treatment.

1.

2.

3.

4.

6.

5.

7.

ug310-5815_7920E_604.indd   12

ug310-5815_7920E_604.indd   12

3/29/06   3:39:46 PM

3/29/06   3:39:46 PM

Summary of Contents for ProHeat Pro-Tech 7920 SERIES

Page 1: ...220 240V Safety Instructions 3 ProductView Accessories 4 Assembly 5 6 17 Routine Maintenance 17 19 Troubleshooting 20 21 Warranty 24 Replacement Parts 23 Consumer Services 22 ug310 5815_7920E_604 indd...

Page 2: ...lso stand behind it with a knowledgeable dedicated Consumer Services department so should you ever have a prob lem you ll receive fast considerate assistance My great grandfather invented the floor sw...

Page 3: ...let Unplug from outlet when not in use and before conducting maintenance or troubleshooting WARNING To reduce the risk of fire electric shock or injury Use indoors only Do not immerse Use only on surf...

Page 4: ...idges on hand so you can clean and protect whenever it fits your schedule Always use genuine BISSELL Advanced Deep Cleaning Formulas Non BISSELL cleaning solutions may harm the machine and void the wa...

Page 5: ...head screwdriver Refer to Assembly Diagram on page 4 Slide upper handle firmly onto lower handle until screwholes are completely aligned Feed bundled power cord through Tool Caddy from caddy s flat si...

Page 6: ...on sprayed through the accessory tools The SmartTemp Ready Light indicates the heater is ON It is found on the front of the handle where it is easy to see while you clean Wait two minutes for the heat...

Page 7: ...not spray cleaning solution or water The powered brush roll at the floor nozzle is designed to enhance cleaning performance The bristle pattern lifts out the deep down dirt while gently grooming carpe...

Page 8: ...be in the forward position to reinstall Rotate the handle to the carrying position to re latch the lid Replace Tank in machine base seating firmly in place Rotate handle back down to the latched posi...

Page 9: ...s PreTreat setting This provides above floor cleaning with the flip of a switch Just choose the cleaning tool or protector applicator attach to the Flex Hose and ProHeat Pro Tech is ready to clean uph...

Page 10: ...either Tools PreTreat or Floor Cleaning PreTreating is recommended to improve cleaning effectiveness for heavily soiled carpet high traffic areas such as hallways and stairs Set the SmartMix Dial to...

Page 11: ...ulled up Note Both the SmartMix Bottle and the clean water Tank must have liquid in them in order for the machine to spray If one is empty the machine will temporarily lose its prime and will not spra...

Page 12: ...ortant different dyes and materials could be damaged or discoloured by a cleaning solution If such a change should occur try a different solution or call a professional If cleaning on Berber Carpet ge...

Page 13: ...e the TurboBrush switch to the BRUSH position This activates the brush when the unit is running Place the tool directly on the soiled surface Apply downward pressure on the tool and pull towards you w...

Page 14: ...colourfastness Examine area when dry If color is affected do not use For upholstery look for manufacturer s cleaning code tag Use on fabrics coded W or WS If coded S or X do not use Not recommended fo...

Page 15: ...PreTreat setting SmartTemp heats the cleaning solution for carpet and bare floor application only It does not heat solution sprayed through the accessory tools Set SmartMix Dial to Normal Choose the...

Page 16: ...dge Gently bend long tab right side outward to easily snap over edge of clear nozzle on left Set up machine following instructions in the Features section on pages 6 9 Be sure to thoroughly rinse out...

Page 17: ...and replace on the machine Clean out Lint Screen Clean out the Flow Indicator Filter each time it is used to ensure best cleaning performance Unscrew the Flow Indicator Cap lift out the Red Rotor and...

Page 18: ...the bottom of the machine near the belt access area is a red retainer plate that holds the black brush arm and brush in place Using a Phillips head screwdriver remove the screw that holds the red ret...

Page 19: ...crew see illustration Using your finger gently spin the Replacement Pump Belt on the silver motor shaft If assembled correctly the Replacement Pump Belt should rotate freely around the silver motor sh...

Page 20: ...ct for presence of seals Pump may have lost prime Turn Power Switch OFF after 1 minute turn ON and depress trigger The Pump Belt may be broken Turn Power Switch OFF and unplug from the outlet To check...

Page 21: ...any residual solution left in the tool SmartMix not set on Water Rinse Set to proper setting Carpet Protector setting ReadyTool Dial not set on Set to Tools PreTreat setting Tools PreTreat setting Cle...

Page 22: ...d Old Windsor Berkshire SL4 2SE United Kingdom Telephone 0870 225 0109 For all other inquiries Monday Friday 8 a m 4 p m EST BISSELL Homecare Inc PO Box 1888 Grand Rapids MI 49501 USA Telephone 01 616...

Page 23: ...Pump Belt With Instructions 17 015 0621 Replacement Brush Belt With Instructions 18 213 3501 Lint Screen 19 0464 Scotchgard Protector Cartridge 20 215 2152 Applicator Tool 21 480 950ml Floor Cleaning...

Page 24: ...s not covered For UK inquiries Monday Thursday 9 am 5 pm Friday 9 am 4 pm BISSELL Homecare Overseas Inc The Boat Yard 105 Straight Road Old Windsor Berkshire SL4 2SE United Kingdom Telephone 0870 225...

Reviews: