Use only BISSELL Style 8 Replacement Belts (#3200C)
in your BISSELL Lift-Off.
Unplug cleaner from electrical outlet.
With Rotating Floor Brush removed from vacuum cleaner
(Steps 1-5 of Check Rotating Floor Brush and Drive Belt),
grasp old Drive Belt and remove from Motor Pulley. Discard
old Drive Belt.
Place new Drive Belt over Motor Pulley and stretch other end
over Rotating Floor Brush in the space between the bristles.
Place ends of Rotating Floor Brush down into slots on sides
as shown.
Turn Rotating Floor Brush by hand several times in the
direction of Motor Pulley. If properly installed, Drive Belt will
center itself on Rotating Brush crown.
Reposition Brush Cover and screws. Tighten screws securely.
Use only BISSELL Replacement Bulb (#203-1007) in
your BISSELL Lift-Off.
Unplug cleaner from electrical outlet.
Remove Detachable Canister and recline Handle of vacuum.
Using a screwdriver, remove the one screw as shown and
lift off the lens.
Remove the bulb from the socket by pushing in gently and
turning it towards brush. Install the new bulb by pushing it
gently into the socket and turning away from brush.
Reposition lens and secure with the one screw.
Select Models Only
If the TurboBrush stops rotating or will not pick up
debris, check for a clog. If a clog is present, unscrew
the two screws in the back of the TurboBrush to remove
the faceplate. Clear any obstructions, reassemble and
replace the two screws.
1.
Replace Drive Belt
12
Replace Light Bulb
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
TurboBrush Maintenance
WARNING:
To reduce the risk of electric
shock, turn Power Switch OFF
and disconnect polarized plug
from electrical outlet before
performing maintenance or
troubleshooting checks.