Special attention: please experience technicians or the company's sales staff, not to
adjust.
If the pressure adjusting screw is rotated clockwise, the use pressure will be increased,
and vice versa.
5.4 Safety valve adjustment:
Special note: the service pressure of the compressor shall not be higher than the rated
working pressure of the compressor. If the adjustment is needed, it must be made by
experienced technicians or the company's business staff, not by themselves.
The relief pressure of the relief valve is generally set higher than the exhaust pressure
of 0.1mpa, so there is no need to adjust it by itself. If it is necessary to adjust the
discharge pressure of the safety valve for other reasons, loosen the lock nut of the
safety valve and adjust the screw again. If the valve is rotated clockwise, the discharge
pressure will be increased; if the valve is rotated counterclockwise, the pressure will be
set down; after setting the discharge pressure, tighten the lock nut.
Chapter VI maintenance and inspection
6.1 Regular inspection and maintenance:
6.1.1 Rlease keep the machine clean;
6.1.2 The drain valve of the gas storage tank should be opened once a day to remove oil
and water, and every four hours in places with heavy humidity.
6.1.3 Check the lubricating oil level once a day to ensure that there is enough
lubricating oil for the air compressor;
6.1.4 Clean or replace the air filter every 15 days (the filter element is consumable);
6.1.5 check the tightness of screws in various parts from time to time;
6.1.6 please replace the lubricating oil after the initial operation of 50 hours or a week,
and replace the lubricating oil every 500 hours (for those with poor operating
environment, replace the oil once every 150 hours), and replace the lubricating oil once
every 36 hours after the operation.
6.1.7 Remove and clean the air valve after 500 hours (or half a year) of use.
6.1.8 Please clean all parts of the machine once a year;
www.italiastar.ro
004/021.433.03.27
Italia Star Com Due S.R.L.
35