7
4.1 FUNCTION OF THE KEYS
- Clears the displayed gross weight if it’s within the configured percentage (see section
7.8.1) of the total capacity.
- A secondary function of "Enter" key when setting parameters or other functions.
- If pressed for an instant it executes the semiautomatic tare;
- A secondary function of incrementing the active digit when setting a value for
parameters or other functions.
- If pressed for an instant it allows to execute the reference operation (see section 6.6)
and then execute the conversion from pieces to weight and vice versa.
- In the numeric or alphanumeric input, it selects the digit to be modified, from left to
right.
- It allows to convert in the configured secondary units of measure (see section 6.8).
- In the numeric or alphanumeric input, it selects the digit to be modified, from left to
right.
-
It allows to enter the set-up environment (see section 7)
-
In the numeric input phase, it quickly clears the present value.
- If pressed for an instant it adds the value to the accumulation memory if the
accumulation function is not automatic.
- Secondary function (ESC) is to return to normal operation when the scale is in a
parameter setting mode.
- Turn on/turn off the power.
4.2 FUNCTION OF THE INDICATORS
INDICATOR
FUNCTION
Charging
Indicates that the battery is going to recharge (see section 3.3).