background image

Page 4 of 12 

 6001099 Birko Tempo Tronic 03.2017 v1.00

c)  Cold water supply with a minimum working pressure of 70 kPa and 

a maximum working pressure of 500 kPa connected via an isolation 

valve.

d)  Outlet drainage to a sink draining board or to a drip tray.
e)  Access to drainage from a vent situated at the base of the heater.
  If the water pressure is likely to exceed 500 kPa, a 350 kPa pressure 

reducing valve must be installed in the cold water supply line.

f)  In all installation instances the walls of the heater must be vertical 

and the base horizontal, there can be no exceptions to this rule.

Before You Begin

Locate the paper mounting-hole template packed with the heater.
Read the installation and operating instructions completely.
Decide whether to install with concealed or exposed plumbing and/or 

electrical connections. Concealed connections are preferred for superior 

appearance.

Step 1 – Positioning

Position the heater so the tap will drain on to a draining board or drip 

tray.
Position the base of the tap to be not less than 200 mm above the 

draining board (height should be increased only if essential for filling 

larger vessels).
Provide clearance for service access of not less than 150 mm top, 65 

mm left, 20 mm right.
Mark corner positions for the heater on the wall so as to position the 

paper mounting-hole template. 

Step 2 – Fastening

Position mounting-hole template on wall and drill holes where shown.

Remove cover fastening screws from heater and lift whole cover off 

heater.
Install plumbing and wiring and prepare pipe ends and wiring ends as 

required.
Screw heater chassis to the wall using screws or bolts suited to the 

walling.
Screws or bolts must be capable of supporting the heater weight when 

filled. (Refer to table to the left).

Installation Procedures

Approximate Weight When Filled

150 mm

minimum 

clearance

20 mm minimum

clearance

from right edge 

to wall

200 mm

65 mm

Installation Requirements 

continued

3 Litre model

12.5 kg

5.0 Litre model

16.5 kg

7.5 Litre model

20.5 kg

15 Litre model

34.5 kg

25 Litre model

47 kg

100 mm

minimum 

clearance

150 mm 

minimum

clearance

from right 

edge to wall

200 mm

20 mm

3L, 5L & 7L

15L, 25L & 40L

Summary of Contents for Tempo Tronic 15L S/S

Page 1: ...1 of 12 1090074 Tempo Tronic 3L S S 1090076 Tempo Tronic 5L S S 1090078 Tempo Tronic 7 5L S S 1090082 Tempo Tronic 15L S S 1090086 Tempo Tronic 25L S S 1100076 Tempo Tronic 5L S S Timer Birko Tempo T...

Page 2: ...ing 5 b Venting 5 c Electrical 6 Step 4 Assembling 6 Step 5 Commissioning 6 Operating Procedures 7 Earthing Continuity Verification 7 Problem Solving 8 Wall Mounting Template Dimensions 9 Cleaning 9 E...

Page 3: ...circumstances without first isolating the heater from the power supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located wher...

Page 4: ...drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access...

Page 5: ...Pa maximum 500 kPa Warning If pressure is likely to exceed 500 kPa a pressure limiting valve must be installed in the cold water supply line Birko recommends a valve rated at 350 kPa for this applicat...

Page 6: ...the way to escutcheon tube then apply PTFE tape to the threaded portion of the outlet tube if not already applied See Fig 1 Screw the tap assembly clockwise onto the outlet tube until it touches the...

Page 7: ...illed without holding your hand where it may be affected by steam Earthing Continuity Verification Warning this appliance must be earthed Following remedial service the earthing continuity of the heat...

Page 8: ...ve Contact Birko authorised agent Water not boiling No power Faulty thermostat faulty element faulty cutout Incorrect timer setting Check power supply Contact Birko authorised agent Check timer settin...

Page 9: ...ld soap and water Wall Mounting Template Dimensions 3 0 L 3 0 L End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your loc...

Page 10: ...l 9b 1312234 Bush vent assy 5l 9c 1312235 Bush vent assy 7 5l 9d 1312236 Bush vent assy 15l 9e 1312237 Bush vent assy 25l 10 1312238 Loom Birko TT Ther Overload 11 1315320 Timer 7day 24Hr Gray 12 1312...

Page 11: ...6001099 Birko Tempo Tronic 03 2017 v1 00 Page 11 of 12 Exploded View Diagram 11 3 4 1 20 6 21 22a 5 10 17 9 18 17 17 14 13 12 19 15 8 7 16 2 22b...

Page 12: ...of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods The st...