Bird Site Analyzer
94
FM Modulation
The Bird Site Analyzer uses FM modulation to
improve its immunity to interfering signals. Under
certain circumstances, such as while making cable loss
or other high reflection measurements with long
cables, FM modulation may reduce signal quality. In
that case, the modulation should be turned off.
y
FM modulation is on by default, and will be turned
back on whenever the unit is reset to defaults.
y
FM modulation is automatically turned off while
the unit is in Cable Loss Mode and returned to its
previous state on exiting Cable Loss Mode.
y
Saving a setup saves the status of the modulation.
Toggle
between ON
and OFF
FM Mod
Rtn To
Defaults
Utility Mode
Rtn To
Defaults
FM Mod
Printer
System
FM Modulation ON
Model SA-2500A, 780 - 2500 MHz
SN: 00000000
8 Feb 2002