BIRD BA-300 Series Operation Manual Download Page 12

3

Chapter 3

Installation

This

 

chapter

 

provides

 

information

 

for

 

on

site

 

requirements,

 

unpacking,

 

inspection,

 

and

 

preparing

 

the

 

unit

 

for

 

use.

Unpacking and Inspection

1.

Carefully

 

inspect

 

shipping

 

container

 

for

 

signs

 

of

 

damage.

 

If

 

the

 

shipping

 

container

 

is

 

damaged,

 

do

 

not

 

unpack

 

the

 

unit.

 

Immediately

 

notify

 

the

 

shipping

 

carrier

 

and

 

Bird

 

Technologies.

If

 

the

 

shipping

 

container

 

is

 

not

 

damaged,

 

unpack

 

the

 

unit.

 

Save

 

shipping

 

materials

 

for

 

repackaging.

2.

Inspect

 

unit

 

for

 

visual

 

signs

 

of

 

damage.

 

Note: 

If

 

there

 

is

 

damage,

 

immediately

 

notify

 

the

 

shipping

 

carrier

 

and

 

Bird

 

Technologies.

Mounting

Place

 

the

 

Blower

 

Assembly

 

in

 

a

 

dry,

 

dust

 

and

 

vibration

 

free

 

environ

ment.

 

Do

 

not

 

use

 

outdoors

 

or

 

in

 

areas

 

of

 

condensing

 

humidity.

 

Allow

 

at

 

least

 

3"

 

(7.6

 

cm)

 

of

 

clearance

 

above

 

and

 

on

 

all

 

sides

 

of

 

the

 

unit.

Bird

 

Blower

 

Assemblies

 

are

 

equipped

 

for

 

either

 

portable

 

use

 

or

 

fixed

 

installation.

 

The

 

mounting

 

brackets

 

on

 

the

 

front

 

and

 

rear

 

faces

 

have

 

four

 

mounting

 

slots

 

arranged

 

in

 

a

 

4

1

2

"

 

x

 

20

 

23

32

"

 

rectangle

 

(114.3

 

x

 

526.3

 

mm).

 

Use

 

a

 

screw

 

with

 

a

 

3

8

"

 

(9.53

 

mm)

 

diameter

 

max.

Installing Thermoswitch (BA–310 Only)

The

 

Bird

 

BA–310

 

requires

 

a

 

control

 

thermoswitch,

 

P/N

 

2450

085,

 

for

 

automatic

 

operation.

 

It

 

is

 

normally

 

open,

 

closing

 

at

 

155

 

°C

 

(311

 

°F),

 

with

 

a

 

rating

 

of

 

10A

 

@

 

120Vac

 

and

 

5A

 

@

 

230Vac.

To

 

install

 

the

 

thermoswitch

 

on

 

the

 

load,

 

proceed

 

as

 

follows:

1.

Replace

 

the

 

vent

 

plug

 

in

 

the

 

load

 

with

 

the

 

shipping

 

plug.

2.

Stand

 

the

 

load

 

on

 

its

 

back

 

with

 

the

 

connector

 

end

 

up.

 

In

 

this

 

position

 

there

 

is

 

no

 

danger

 

of

 

the

 

coolant

 

pouring

 

out

 

through

 

the

 

socket

 

plug

 

hole.

3.

Remove

 

the

 

top

 

socket

 

plug

 

using

 

a

 

9

16

"

 

hex

 

wrench.

4.

Replace

 

the

 

plug

 

with

 

the

 

thermoswitch.

 

Sparingly

 

apply

 

pipe

 

sealing

 

compound

 

to

 

the

 

external

 

threads,

 

only,

 

of

 

the

 

thermoswitch.

 

Do

 

not

 

contaminate

 

the

 

coolant

 

with

 

pipe

 

sealant.

5.

Check

 

for

 

coolant

 

leaks

 

upon

 

completion.

CAUTION

The

 

BA

 

system

 

is

 

designed

 

for

 

operation

 

in

 

a

 

horizontal

 

position

 

only,

 

with

 

the

 

load’s

 

vent

 

plug

 

up.

 

Do

 

not

 

use

 

in

 

any

 

other

 

manner.

WARNING

Disconnect

 

the

 

unit

 

from

 

all

 

power

 

sources

 

before

 

servicing.

The

 

unit

 

may

 

be

 

energized

 

from

 

multiple

 

sources.

The

 

potential

 

for

 

electric

 

shock

 

exists.

WARNING

The

 

vent

 

plug

 

must

 

be

 

used

 

at

 

all

 

times

 

when

 

the

 

load

 

is

operating

 

or

 

cooling.

 

Failure

 

to

 

do

 

so

 

could

 

result

 

in

 

an

explosion

 

or

 

severe

 

burns.

Summary of Contents for BA-300 Series

Page 1: ...bly Models BA 300 BA 310 Operation Manual Copyright 2016 by Bird Technologies Inc Instruction Book Part Number 920 BA 300 310 Rev G Termaline and Tenuline are Registered Trademarks of Bird Electronic...

Page 2: ...remove the RF transmission line while RF power is present WARNING Do Not Service Or Adjust Alone Under no circumstances should any person reach into an enclosure for the purpose of service or adjustm...

Page 3: ...onal injury CAUTION Caution notes call attention to a procedure which if not correctly performed could result in damage to the instrument The caution symbol appears on the equipment indicating there i...

Page 4: ...d is operating or cooling Failure to do so could result in an explosion or severe burns WARNING Disconnect the unit from all power sources before servicing The unit may be energized from multiple sour...

Page 5: ...with the load s vent plug up Do not use in any other manner CAUTION If installed connect optional interlock before applying RF power CAUTION Check the local electrical code for proper ac hookup prior...

Page 6: ...RIDAD DEL INSTRUMENTO BENUTZUNG WIRD DAS GER T AUF ANDERE WEISE VERWENDET ALS VOM HERSTELLER BESCHRIEBEN KANN DIE GER TESICHERHEIT BEEINTR CHTIGT WERDEN UTILISATION TOUTE UTILISATION DE CET INSTRUMENT...

Page 7: ...S GER TES GELTEN NUR F R GESCHULTES FACHPERSONAL ZUR VERMEIDUNG GEF HRLICHE ELEKTRISCHE SCHOCKS SIND WARTUNGSARBEITEN AUSSCHLIE LICH VON QUALIFIZIERTEM SERVICEPERSONAL DURCHZUF HREN ENTRENTIEN L EMPLO...

Page 8: ...refer to the part number and revision on the title page Chapter Layout Introduction Describes the features of the blower lists equipment supplied and optional equipment Theory of Operation Describes t...

Page 9: ...pter 3 Installation 3 Unpacking and Inspection 3 Mounting 3 Installing Thermoswitch BA 310 Only 3 Thermoswitch Connection BA 310 Only 4 Load Resistor 5 AC Power Hookup 5 Chapter 4 Operating Instructio...

Page 10: ...a thermoswitch wired in parallel with the power switch When a load equipped with a fan control thermoswitch is properly connected the blower will automatically turn on in response to a rise in load te...

Page 11: ...er Assembly baffles cover the radiator fins so that the high airflow generated by two blower fans is confined to passing over the fins Up to twice as much RF energy can be dissipated by this forced dr...

Page 12: ...8 9 53 mm diameter max Installing Thermoswitch BA 310 Only The Bird BA 310 requires a control thermoswitch P N 2450 085 for automatic operation It is normally open closing at 155 C 311 F with a ratin...

Page 13: ...he base 2 Thread the control switch wires through the clamp E with the washers F inside and with its threaded fitting in place Service the control switch wire with short tips and put spaghetti sleeves...

Page 14: ...e It may be necessary to temporarily loosen the two screws in the unremoved vertical panel Tighten all the side panel and base mounting screws securely Push the power cable s plug into the socket at t...

Page 15: ...NUAL momentarily to check that the fans are working properly Apply RF power Operation Under Abnormal Conditions If the indicator light turns off or the fans stop unexpectedly immediately turn off the...

Page 16: ...at the source If the load is equipped with an interlock thermoswitch RF power will be automatically turned off when the coolant temperature reaches an unsafe level Use of an interlock thermoswitch is...

Page 17: ...assembly it will be necessary to partially disassemble the blower to clean the load s radiator fins Follow the instructions below WARNING Never attempt to connect or disconnect RF equipment from the t...

Page 18: ...lude stuck or blocked fans or a short circuit in the motor or blower wiring Press the locking tab on the fuse drawer and remove the drawer Replace the fuse See Specifications on page 12 for fuse type...

Page 19: ...not to lose the lipped retaining washers 5 Insert the replacement fan with the fan blade assembly facing down towards the fan guard grill 6 Insert the mounting screws and retaining washers into the mo...

Page 20: ...embly by itself pack it in a sturdy corrugated paper shipping carton If it is attached to a load a wood crate is recommended because of size and weight Customer Service Any maintenance or service proc...

Page 21: ...ad in place 215 8 L x 73 8 W x 171 4 H 548 x 187 x 436 mm Weight Nominal 13 5 lb 6 1 kg Finish Grey Powder Coat DESCRIPTION QTY PART NUMBER Control Thermoswitch BA 310 only 1 2450 085 Side Panel Screw...

Page 22: ...ry such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing within ten days from the date of discovery of the defect The above warranties shall not extend...

Reviews: