Channel Power Sensor 4042
5
3.
Connect 4042's RF output connector to the antenna cable.
4.
Repeat step
through
for any additional 4042 power sensors.
5.
Install RJ-25 termination plug in unused digital sensor RJ-25 port on the rear
panel of the CPM (if available), or in the last sensor installed in the digital
sensor chain.
6.
Connect a data/power cable from the CPM to 4042 power sensor.
Note:
Each digital sensor must have a unique RS-485 Bus address
when connected serially to the CPM. Connect the digital sensors
one at a time, enroll the sensor using the CPM front panel to
provide a unique address, prior to connecting additional sensors.
7.
Configure the sensor via CPM front panel. Refer to the CPM Operation
Manual.
8.
If additional 4042 power sensors will be connected, connect a data/power
cable to the open RJ-25 jack, connect remaining end of cable to additional
4042 sensor.
9.
Repeat step
through
for any additional 4042 power sensors serially
connected to the CPM.
Note:
Digital sensors require a terminator plug be installed in the
open Digital Sensor RJ-25 port on the rear panel of the CPM (if
available), or in the last sensor installed in the digital sensor chain.
10. If required, install RJ-25 termination plug in unused RJ-25 Jack of last digital
sensor in the chain.