background image

Remote control

V

alue 1

V

alue 2

V

alue 3

V

alue 4

V

alue 5

V

alue 6

V

alue 7

V

alue 8

V

alue 9

Fa

ct

or

de

fa

ul

t s

et

ting

B + Nr

.: beam

Displayed and 

selected as «on»

or «off» using

keys 1 and 2

B + 1: beam 1

 

B + 2: beam 2 

B + 3: beam 3

B + 4: beam 4

B + 5: beam 5

B + 6: beam6

B + 7: beam 7

 

B + 8: beam 8

B + 9: 

all beams on

 

 

Power saving mode

3

S

e

tt

in

g

 o

p

ti

o

n

s

 u

s

in

g

 k

e

y

s

 &

 r

e

m

o

te

 c

o

n

tr

o

l:

 

P

a

ra

m

e

te

2

li

g

h

p

o

in

ts

:

Legend for sensor keys and LEDs:

4

= Red LED  

= Red key

%

= Green LED  

= Green key

V

alue 1:

V

alue 2:

V

alue 3: 

V

alue 4: 

V

alue 5:

V

alue 6: 

V

alue 7:  

V

alue 8: 

V

alue 9:  

Notes:

Remote

control 

1

2

3

4

5

6

7

8

9

Sensor

keys

%

fla

sh

es

1x

%

fla

sh

es

 2

x

%

fla

sh

es

 3

x

%

fla

sh

es

 4

x

%

fla

sh

es

 5

x

%

fla

sh

es

 6

x

%

fla

sh

es

 7

x

%

fla

sh

es

 8

x

%

fla

sh

es

9x

A number is assigned to

each value

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

After value 9, returns to

value 1

Re

m

ot

co

nt

Sensor keys

A

4

Fl

as

1x

High aktive

pull up

High aktive

pull down

Low aktive

pull up

Low aktive

pull down

*

off

pr

es

1x

  

4

fla

sh

es

 2

x

See tables below for all settings

C

pr

es

1x

  

4

fla

sh

es

 3

x

Relay active

circuit

*

Relay 

passive circuit

 –

reboot

SW

-version

D

pr

es

1x

  

4

fla

sh

es

 4

 

10 cm

15 cm

20

 c

m

30 cm

*

40 cm

50 cm

70 cm

E

pr

es

1x

  

4

fla

sh

es

 5

 

0 ms

50 ms

200 ms

*

500 ms

1 s

3 s

6 s

10 s

Relay drop-out delay

F + 1

pr

es

1x

  

4

fla

sh

es

 6

x

1

2

*

3

4

5

6

7

D

ev

ic

ad

dr

es

af

te

r i

ni

ti.

:

master=3 slave= 4

- 7

F + 2

pr

es

1x

  

4

fla

sh

es

 7

x

standard

Floor:

dark/

reflecting

Floor:

Metal grating

(use a base

when making

settings)

When making set-

tings for a metal gra-

ting, the sensitivity is

fixed at >= 50 cm 

– attend to safety 

requirements 

F + 3

pr

es

1x

  

4

fla

sh

es

 8

x

Mount. height

1.4 – 1.7 m

approx.

Mount. height

1.7 – 2 m

approx.

Mount. height

2 – 2.4 m

approx.

Mount. height

2.4 – 3.0 m 

approx.

Te

ac

h-

in

 h

ei

gh

t

or

 p

re

ss

 th

e

«r

ed

» 

ke

fo

r 1

 s

M

a

st

e

r

in

it

ia

li

sa

ti

o

n

or

 p

re

ss

 th

«g

re

en

»

ke

y f

or

 5

 s

LED-test

RegloBeam 2

off

V

alue 1 – 4 for display

purposes only

F + 4

pr

es

1x

  

4

fla

sh

es

 9

x

*

synch

No synch

standby &

synch

 –

Off if release 3 or US

beam is combined with

older devices

F + 8

Standard

mode

*

Power

saving mode

S

e

le

c

t e

n

h

a

n

c

e

d

 le

ve

l =

p

a

ra

m

e

te

rs

 s

e

t t

o

 fa

c

to

ry

d

e

fa

u

lt

 s

e

tt

in

g

s

3

6

4

5

StartStart

 

The setting options available via the remote control and sensor keys differ for parameter 2. Individual beams can be switched o

ff and on us

ing the remote control, whilst light beam patterns can be set using the «red»

and «green» keys. 

If light beams are switched on or off, the «height teach-in» function 

must be executed. 

With sensitivity levels 6 and 7, the sensor only has access to 7 light beams; beam 8 is deactivated.

2

Light beams

 

 

Sensor keys

V

alue 1: 

V

alue 2: 

V

alue 3: 

V

alue 4: 

V

alue 5:

V

alue 6:

V

alue 7:

V

alue 8:

V

alue 9:

A

fte

r p

ar

am

et

er

 1

,

pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

 

Pr

es

1x

4

fla

sh

es

2x

%

flashes1x

%

flashes

2x

%

flashes

3x

%

flashes

4x

%

flashes

5x

%

flashes

6x»

%

flashes7x

%

flashes

8x

%

flashes 9x

Factory default 

setting

 

 

 

 

 

 

Display of 

special pattern

 

Power saving mode

2

Light beams

Parameter 2 using the remote control

Parameter 2 using the «red» and «green» keys

Setting mode using keys:

Press the red and green keys for at least 1 s.

Exit by pressing red and green again for 1 s.

Setting mode using remote control:

Press key G

Set 

value

Select 

parameter

1.

2.

1

Test input

2

Light beams

3

Output

4

Sensitivity

5

Relay hold  interval

6

Device 

address

7

Nature of the

background

(ground)

8

Initialisation

9

Synchronisa- tion mode

En

ha

nc

ed

 le

ve

ls

(v

ia

 re

m

ot

e

co

nt

ro

l o

nl

y)

Factory default setting  *As-delivered condition

  Key 1 = on

  Key 2 = off

  Key 1 = on

  Key 2 = off

  Key 1 = on

  Key 2 = off

  Key 1 = on

  Key 2 = off

  Key 1 = on

  Key 2 = off

  Key 1 = on

  Key 2 = off

  Key 1 = on

  Key 2 = off

  Key 1 = on

  Key 2 = off

Note: If parameters are changed, an initialisation procedure must always be performed on the corresponding sensor module.

DIN 18650

DIN 18650

DIN 18650

DIN 18650

DIN 18650

DIN 18650

DIN 18650

DIN 18650

DIN 18650

DIN 18650

DIN 18650

DIN 18650

= Fulfills DIN 18650 installed moving

DIN 18650

Reviews: