Remote control
V
alue 1
V
alue 2
V
alue 3
V
alue 4
V
alue 5
V
alue 6
V
alue 7
V
alue 8
V
alue 9
Fa
ct
or
y
de
fa
ul
t s
et
ting
B + Nr
.: beam
Displayed and
selected as «on»
or «off» using
keys 1 and 2
B + 1: beam 1
B + 2: beam 2
B + 3: beam 3
B + 4: beam 4
B + 5: beam 5
B + 6: beam6
B + 7: beam 7
B + 8: beam 8
B + 9:
all beams on
Power saving mode
3
S
e
tt
in
g
o
p
ti
o
n
s
u
s
in
g
k
e
y
s
&
r
e
m
o
te
c
o
n
tr
o
l:
P
a
ra
m
e
te
r
2
,
li
g
h
t
p
o
in
ts
:
Legend for sensor keys and LEDs:
4
= Red LED
= Red key
%
= Green LED
= Green key
V
alue 1:
V
alue 2:
V
alue 3:
V
alue 4:
V
alue 5:
V
alue 6:
V
alue 7:
V
alue 8:
V
alue 9:
Notes:
Remote
control
1
2
3
4
5
6
7
8
9
Sensor
keys
%
fla
sh
es
1x
%
fla
sh
es
2
x
%
fla
sh
es
3
x
%
fla
sh
es
4
x
%
fla
sh
es
5
x
%
fla
sh
es
6
x
%
fla
sh
es
7
x
%
fla
sh
es
8
x
%
fla
sh
es
9x
A number is assigned to
each value
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
After value 9, returns to
value 1
Re
m
ot
e
co
nt
.
Sensor keys
A
4
Fl
as
h
1x
High aktive
pull up
High aktive
pull down
Low aktive
pull up
Low aktive
pull down
*
off
–
–
–
–
pr
es
s
1x
4
fla
sh
es
2
x
See tables below for all settings
C
pr
es
s
1x
4
fla
sh
es
3
x
Relay active
circuit
*
Relay
passive circuit
–
–
–
–
reboot
SW
-version
–
D
pr
es
s
1x
4
fla
sh
es
4
x
10 cm
15 cm
20
c
m
30 cm
*
40 cm
50 cm
70 cm
–
–
E
pr
es
s
1x
4
fla
sh
es
5
x
0 ms
50 ms
200 ms
*
500 ms
1 s
3 s
6 s
10 s
–
Relay drop-out delay
F + 1
pr
es
s
1x
4
fla
sh
es
6
x
1
2
*
3
4
5
6
7
–
–
D
ev
ic
e
ad
dr
es
s
af
te
r i
ni
ti.
:
master=3 slave= 4
- 7
F + 2
pr
es
s
1x
4
fla
sh
es
7
x
standard
*
Floor:
dark/
reflecting
Floor:
Metal grating
(use a base
when making
settings)
–
–
–
–
–
–
When making set-
tings for a metal gra-
ting, the sensitivity is
fixed at >= 50 cm
– attend to safety
requirements
F + 3
pr
es
s
1x
4
fla
sh
es
8
x
Mount. height
1.4 – 1.7 m
approx.
Mount. height
1.7 – 2 m
approx.
Mount. height
2 – 2.4 m
approx.
Mount. height
2.4 – 3.0 m
approx.
Te
ac
h-
in
h
ei
gh
t
or
p
re
ss
th
e
«r
ed
»
ke
y
fo
r 1
s
M
a
st
e
r
in
it
ia
li
sa
ti
o
n
or
p
re
ss
th
e
«g
re
en
»
ke
y f
or
5
s
LED-test
RegloBeam 2
off
V
alue 1 – 4 for display
purposes only
F + 4
pr
es
s
1x
4
fla
sh
es
9
x
*
synch
No synch
standby &
synch
–
–
–
–
–
–
Off if release 3 or US
beam is combined with
older devices
F + 8
–
Standard
mode
*
Power
saving mode
–
–
–
–
–
–
S
e
le
c
t e
n
h
a
n
c
e
d
le
ve
l =
p
a
ra
m
e
te
rs
s
e
t t
o
fa
c
to
ry
d
e
fa
u
lt
s
e
tt
in
g
s
3
6
4
5
StartStart
The setting options available via the remote control and sensor keys differ for parameter 2. Individual beams can be switched o
ff and on us
ing the remote control, whilst light beam patterns can be set using the «red»
and «green» keys.
If light beams are switched on or off, the «height teach-in» function
must be executed.
With sensitivity levels 6 and 7, the sensor only has access to 7 light beams; beam 8 is deactivated.
2
Light beams
Sensor keys
V
alue 1:
V
alue 2:
V
alue 3:
V
alue 4:
V
alue 5:
V
alue 6:
V
alue 7:
V
alue 8:
V
alue 9:
A
fte
r p
ar
am
et
er
1
,
pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
Pr
es
s
1x
4
fla
sh
es
2x
%
flashes1x
%
flashes
2x
%
flashes
3x
%
flashes
4x
%
flashes
5x
%
flashes
6x»
%
flashes7x
%
flashes
8x
%
flashes 9x
Factory default
setting
Display of
special pattern
Power saving mode
2
Light beams
Parameter 2 using the remote control
Parameter 2 using the «red» and «green» keys
Setting mode using keys:
Press the red and green keys for at least 1 s.
Exit by pressing red and green again for 1 s.
Setting mode using remote control:
Press key G
Set
value
Select
parameter
1.
2.
1
Test input
2
Light beams
3
Output
4
Sensitivity
5
Relay hold interval
6
Device
address
7
Nature of the
background
(ground)
8
Initialisation
9
Synchronisa- tion mode
En
ha
nc
ed
le
ve
ls
(v
ia
re
m
ot
e
co
nt
ro
l o
nl
y)
Factory default setting *As-delivered condition
Key 1 = on
Key 2 = off
Key 1 = on
Key 2 = off
Key 1 = on
Key 2 = off
Key 1 = on
Key 2 = off
Key 1 = on
Key 2 = off
Key 1 = on
Key 2 = off
Key 1 = on
Key 2 = off
Key 1 = on
Key 2 = off
Note: If parameters are changed, an initialisation procedure must always be performed on the corresponding sensor module.
DIN 18650
DIN 18650
DIN 18650
DIN 18650
DIN 18650
DIN 18650
DIN 18650
DIN 18650
DIN 18650
DIN 18650
DIN 18650
DIN 18650
= Fulfills DIN 18650 installed moving
DIN 18650