Configuration fall-delay time
6.3
Display
Fall-delay time
001
none
002
100 ms
003
*
200 ms
004
500 ms
005
1000 ms
Most important technical data
8
Press the «Mode» button briefly.
Use the «Data» button to set the required
fall-delay time
(according to Table 2).
Then briefly press the «Mode» button and End appears.
➔
The system is configured.
➔
Press «Data» button to restart.
Configuration mode (for configuration before starting up,
via diagnostic menu, after mode «h»)
6
Please read chapters 6.1 to 6.3 in full before attempting configuration.
Configuration of safety edge inputs
6.2
Table 2
Display
E001
E002
E003
E004
E005
E006
E007
E101/ E102
Error
Safety edge (SE)
malfunction
SE mal-
function
SE mal-
function
SE mal-
function
Cable circuit
malfunction
Mounting
≠
config.
mode
Outputs not OK
Undervoltage/
overvoltage
Remedy
Check
safety edge
Check
SE
Check
SE
Check
SE
Check cable
circuit < 3 ohm
Check
configuration
Check connection
for outputs
Check supply
1
2
Error displays
7
If an error is detected then the outputs are deactivated and symbols
&
and an error code are displayed. The status LED lights up red.
Should other fault messages appear, please contact your supplier.
Configuration menu
can be
exited
at any time by pressing the
«Mode» button (2 s).
«End» is displayed
➔
Press «Data» button and release
➔
Restart undertaken with new configuration.
Error messages may occur when restarting
after configuration if the inputs do not match
the configuration.
Activating configuration menu
6.1
Status LED flashes orange,
press «Data» button
Press the «Mode» and «Data» buttons
simultaneously for 2 s.
Configuration menu is activated.
Use the «Data» button to set the
configuration
you want for the safety edge inputs
(according to Table 1).
The current setting for the safety edge
inputs is displayed.
Display
Mobile
safety
edge
CLOSE
Mobile
safety
edge
OPEN
Stationary
safety
edge
CLOSE
Stationary
safety
edge
OPEN
not configured
001*
X
X
X
002
X
X
X
X
003
X
X
004
X
X
005
X
006
X
X
X
007
X
X
X
008
X
X
009
X
X
010
X
011
X
UNC
*)
F
ac
to
ry
s
et
ti
ng
Table 1
*)
F
ac
to
ry
s
et
ti
ng
Operating voltage
InTra6 3
24 V AC/DC ± 15%,
InTra6 3.LVAC
100-240 V AC
50/60 Hz
Power consumption
max. 3 VA
Safety edges
8,2 kOhm
Outputs
Semiconductor relay, 24 V DC, max. 50 mA
Dimensions
(W x H x D)
Switching device
22,5x94x88 mm
Coil
:
50x25x22 mm
Converter
:
40x25x22 mm
Electrical installation
9.1
Mechanical mounting
9.2
Mounting
9
1. Check that electrical components are all present by referring to component list 9.3.
2. Mount switching device in designated position.
3. Mounting of mechanical parts (see chapters 9.2 and 9.3).
4. Connect electrical lines as shown in terminal diagram in chapter 2.
1. Check that mechanical components are all present by referring to component list 9.3
2. Mount the two mounting brackets
and the coil
.
3. Pull in the steel cable (see chapter 9.4 and 9.5). Mount converter INTR-MOB
or
.
4. Tension the steel cable
cable and fix it via the retaining screw
. The steel cable
must be able to move unimpeded
through the INTR-FIX60 coil
along the full length of the gate.
5. Connect steel cable
as described in chapter 9.5. Make sure the connection with the gate offers low resistance
(clean the contact points and remove any paint).
6. Establish the electrical connection as shown in the terminal diagram in chapter 2.