3
1
2
ON
1 2
+
+
2032
2032
ON
1 2
+
2032
1 2
ON
i
ON
OK?
1
2 3 4
5
ON
2x
i
1 2 3 4 5
ON
1
2 3 4
5
ON
2x
2x
6.2. RFGate 2.2.NG, pairing transmitter with receiver
5
Start-up
6
Programming
2.
On the
transmitter
Press and
release button
Beep
Wait
2
beeps
10 sec.
1.
On the receiver
Press
button
Beep
> 1.5 sec.
LED
lights up
6.
Transmitter:
install
Release
button
4.
Transmitter:
insert
batteries
1.
Check DIP
switch settings
5.
Programming (Chapter 6.1):
pair transmitter with receiver
The distance between transmitter
and receiver and further trans-
mitters must be at least 1 m
Observe
order
Code saved
LED goes out
Please observe the torque when
fastening the cover:
Max. 45 N cm
7.
Transmitter:
wire
3.
Turn on power
supply
2.
Install and wire
receiver
8.
System test of safety
edge on gate
6.1 RFGate 2.2.A, pairing transmitter with receiver
2.
On the trans-
mitter for
channel 1
On the
receiver
On the
receiver
On the
receiver
Press and
release button
Beep
Wait
2
beeps
10 sec.
4.
On the trans-
mitter for
channel 2
Press and
release button
Beep
Wait
10 sec.
3.
On the receiver
Beep
Beep
Release
button
Release
button
LED
lights up
LED
flashes
Press
button
> 1,5 sec.
Press
button
> 1.5 sec.
1.
On the receiver
Press
button
Beep
> 1.5 sec.
LED
lights up
Release
button
2
beeps
Code saved
LED goes out
Code saved
LED goes out
Beep
Beep
Beep
Beep
Beep
Beep
Beep
Beep
Beep
Beep
Status
Terminals
COMx – OUTx
Terminals
COMx – SOUTx
Sensor not activated (operating mode)
8K2
closed
Sensor activated (security system activated)
closed
open
No supply voltage
closed
open
Transmitter and receiver not paired
closed
open
Broken cable between sensor and transmitter
closed
open
Transmitter batteries low
closed
open