PrimeTec B / PrimeScan B
Cable
–
+
–
+
–
+
3 m
–
+
1 2
1 2
1 2
1 2
1 2
LCD
1 2
1
Radar
AIR
BBC Bircher Smart Access
, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com
1 / 2
Prime
Tec
B
Prime
Scan
B
Short guide
ENGLISH
299140D
01/19
PrimeScan B
PrimeTec B
Please mind the original manual!
Electrical connections
Configuration using programming buttons (Operator buttons)
Presetting
Automatic
Config. mode
Choose
Choose
Funct./Parameter
Back to choice
Back to autom.
Operator buttons
red
(Function)
black
(Value)
A:
Automatic mode
t:
Test active
Radar
output on
AIR
output on
Press shortly both
buttons
simultaneously
Red button:
switch
between Radar, AIR
and general
Black button:
choose
Red button:
Choose
parameter
Black button:
Choose value of the
parameter
Press both
buttons
Press both
buttons
Switches to automatic
mode (A) automatically
after 1 min
General
Radar functions (PrimeTec)
OPERATION OF THE BUTTONS
1
DESCRIPTION
LCD
Field size
1
1 – 5
1
= Smallest radar field,
.......,
* = Medium radar field,
......,
= Largest radar field
Direction recognition
2
1 – 2
1
= both directions
* = forward
Cross Traffic Optimisation CTO
(
C
ross
T
raffic
O
ptimisation)
4
1 – 2
1
* = Off
= On (recommended only at narrow field)
Door filter
6
1 – 2
1
* = Filter off
= Door and interference filter on (EMV flows, e.g. fluorescence tube)
Radar output
7
1 – 2
1
* = active
= passive
The Slow Motion Detection (SMD) is a factory setting. The SMD recognises slow motions after the detecor has been activated.
AIR functions
(PrimeTec / PrimeScan)
OPERATION OF THE BUTTONS
1
DESCRIPTION
Function
Value
LCD
Set sensitivity
1
1 – 5
2
= high sensitivity (acc. to EN 16005 ≤ 3m, only indoors)
= medium sensitivity (acc. to EN 16005 ≤ 3m)
= low sensitivity (acc. to EN 16005 ≤ 2.3m)
* = normal sensitivity (acc. to EN 16005 ≤ 2.6m)
= very low sensitivity
Set teach-in time
2
1 – 5
2
= 10 s
* = 30 s (acc. to EN 16005)
= 60 s (acc. to DIN 18650 + AS 5007)
= 180 s
= 15 min
AIR output contact logic
3
1 – 4
2
= active (NO)
no detection
contact open
* = passiv (NC)
no detection
contact closed
Series connection
Settings
Master
➔
Slave
Master
➔
Slave
Wiring: See series connection diagram:
reglomat.bircher.com/en/
products-technologies/primefamily-b
AIR output
4
1 – 2
2
* = On
= Off (AIR is going to be reactivated automatically after 15 minutes)
General functions
(PrimeTec / PrimeScan)
OPERATION OF THE BUTTONS
1
DESCRIPTION
Function
Value
LCD
Reset
+
Press both buttons 8
seconds
Initialisaiton and teaching of the background
Presetting
(After presetting and leaving
config. a reset will be done automatically)
1
1 – 8
Press value for
1 second
to change the
presetting
1 2
= Standard,
= footpath,
= home for the aged,
= wind screen,
= high door,
= narrow door,
= wide door,
= factory settings
For all values set,
parameter 0 is displayed
Combined outputs
activated / not activated
2
1 – 2
1 2
= activated (radar and AIR actuate the radar output)
* = not activated
AIR-frequency
(In the case of
overlapping AIR fields consider the
addressing order:
➔
odd nr. 1
➔
even nr. 2
➔
odd nr. 3)
3
1 – 6
2
1
* = Frequency 1
= Frequency 3
= Frequency 5
= Frequency 2
= Frequency 4
= Frequency 6
In the case of overlapping AIR fields consider the frequency order:
➔
odd number
➔
even number
➔
odd number
1
Press both buttons shortly for configuration mode /
* Factory setting
Standard
Foot path
Home for the aged Wind screen
High door
Narrow door
Wide door
Factory settings
Radar field size
3
3
3
2
4
2
5
3
Field geometry
2
wide
narrow
wide
wide
wide
narrow
wide
wide
Cross Traffic Optimisation
1
2
1
1
1
1
1
1
2
Field geometry has to be set manually
Power Supply
1 white
white
2 brown
brown
3 green
green
4 yellow
6 pink
pink
5 grey
grey
yellow
7 blue
blue
8 red
red
Radar output
Test
11.5 – 32 VDC
Controller
Radar
Test
AIR
AIR output