PrimeTec B / PrimeScan B

Cable

+

+

+

3 m

+

1 2

1 2

1 2

1 2

1 2

LCD

1 2

1

Radar

AIR

BBC Bircher Smart Access

, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com

 

1 / 2

Prime

Tec

 B

Prime

Scan

 B

      Short  guide

ENGLISH

299140D

01/19

PrimeScan B

PrimeTec B

Please mind the original manual!

Electrical connections

Configuration using programming buttons (Operator buttons)

Presetting

Automatic

Config. mode

Choose

Choose

Funct./Parameter

Back to choice

Back to autom.

Operator buttons   

red

 (Function) 

black

 (Value) 

A:  

Automatic mode

t:  

Test active

 

Radar  

 

output on

 

AIR 

 

output on

Press shortly both 

buttons 

simultaneously

Red button:

switch  

between Radar, AIR 

and general

Black button:

choose

Red button: 

Choose 

parameter 

Black button: 

Choose value of the 

parameter

Press both 

buttons

Press both 

buttons

Switches to automatic 

mode (A) automatically 

after 1 min

General

Radar functions (PrimeTec)            

OPERATION OF THE BUTTONS

1

DESCRIPTION

LCD

Field size

1

1 – 5

1

 = Smallest radar field, 

 .......,  

* = Medium radar field,  

 ......,  

 = Largest radar field

Direction recognition

2

1 – 2

1

  

 = both directions  

* = forward

Cross Traffic Optimisation CTO  

(

C

ross 

T

raffic 

O

ptimisation)

4

1 – 2

1

* = Off 

  

 = On (recommended only at narrow field)

Door filter

6

1 – 2

1

* = Filter off

  

 = Door and interference filter on (EMV flows, e.g. fluorescence tube)

Radar output

   

7

1 – 2

1

* = active 

   = passive

The Slow Motion Detection (SMD) is a factory setting. The SMD recognises slow motions after the detecor has been activated.

AIR functions  

(PrimeTec / PrimeScan)                      

OPERATION OF THE BUTTONS

1

DESCRIPTION

Function

Value

LCD

Set sensitivity

1

1 – 5

2

  

 =  high sensitivity (acc. to EN 16005 ≤ 3m, only indoors)  

   =  medium sensitivity (acc. to EN 16005 ≤ 3m) 

 

= low sensitivity (acc. to EN 16005 ≤ 2.3m)

* =  normal sensitivity (acc. to EN 16005 ≤ 2.6m)   

 

= very low sensitivity

Set teach-in time

2

1 – 5

2

 = 10 s   

* = 30 s (acc. to EN 16005)   

 = 60 s (acc. to DIN 18650 + AS 5007)  

 = 180 s    

 = 15 min

AIR output contact logic

    

3

1 – 4

2

 

= active (NO)

 

    no detection

 

    contact open

*  = passiv (NC)

 

  no detection

 

  contact closed

Series connection

Settings

Master 

 

➔ 

Slave 

Master 

 

➔ 

Slave 

Wiring: See series connection diagram: 

reglomat.bircher.com/en/ 

products-technologies/primefamily-b

AIR output

4

1 – 2

2

* = On

   = Off (AIR is going to be reactivated automatically after 15 minutes)

General functions  

(PrimeTec / PrimeScan)                 

 

OPERATION OF THE BUTTONS

1

DESCRIPTION

Function

Value

LCD

Reset

+

Press both buttons 8 

seconds

Initialisaiton and teaching of the background

Presetting

 (After presetting and leaving 

config. a reset will be done automatically) 

1

1 – 8

Press value for 

1 second  

to change the 

presetting

1 2

 = Standard, 

 = footpath, 

 = home for the aged, 

 = wind screen, 

 = high door, 

 = narrow door, 

 = wide door, 

 

= factory settings

For all values set, 

parameter 0 is displayed

Combined outputs

activated / not activated

2

1 – 2

1 2

   = activated (radar and AIR actuate the radar output) 

* = not activated

AIR-frequency

  

 (In the case of 

overlapping AIR fields consider the 

addressing order: 

 odd nr. 1 

 even nr. 2 

 odd nr. 3)

3

1 – 6

2

1

* = Frequency 1 

 = Frequency 3 

 = Frequency 5

  

 = Frequency 2 

 = Frequency 4  

 = Frequency 6

 In the case of overlapping AIR fields consider the frequency order: 

 odd number  

 

 even number 

 

 odd number 

1

 Press both buttons shortly for configuration mode / 

* Factory setting

Standard

Foot path

Home for the aged Wind screen

High door

Narrow door

Wide door

Factory settings

Radar field size

3

3

3

2

4

2

5

3

Field geometry

2

wide

narrow

wide

wide

wide

narrow

wide

wide

Cross Traffic Optimisation

1

2

1

1

1

1

1

1

2

 Field geometry has to be set manually

Power Supply

1 white

white

2 brown

brown

3 green

green

4 yellow

6 pink

pink

5 grey

grey

yellow

7 blue

blue

8 red

red

Radar output

Test

11.5 – 32 VDC

Controller

Radar

Test

AIR

AIR output