Initialisation

Remove all objects that do not form part of the usual door system environment from the

door area BEFORE switching on the power supply. Ensure that no people are in the door

area, otherwise correct startup will not be possible.

The alternate flashing shows the initialisation (teaching) of the detector. (Duration 20 - 25 seconds).

During startup, the firmware version FXXX is displayed.

Following initialisation, the red/green LED only illuminates when a detection has occurred.

The door system is now operational at this point.

 If any further settings are required, proceed as described in the following sections.

red LED 

green LED

Mechanical fine tuning

AIR field (PrimeTec / PrimeScan)

Settings of the inclination angle on the

adjustment screw:   

Inclination:

 – 5° ...  +7° continuously adjustable

Radar field (PrimeTec)

Manual settings of the

inclination angle

0° ... +90° in 5° steps

Manual settings of the

pivot angle

– 20° ... +20° in 5° steps

Wide radar field 

 

    

     

turn 90°

 

           Narrow radar field

Inclination angle: 35°

Inclination angle: 35°

min. = 0.5 m x 0.25 m (WxD)

max. = 4 m x 2 m (WxD)

min. = 0.16 m x 0.8 m (WxD)

max. = 2 m x 4 m (WxD)

Setting the AIR field width (PrimeTec / PrimeScan)

A, D covered

A, C, D covered

C, D covered

A, B, D covered

A, B covered

Field width: 

1 x 0.2 m

Field width: 

0.5 x 0.2 m

Field width: 

1.2 x 0.2 m

Field width: 

0.5 x 0.2 m

Field width: 

1.2 x 0.2 m

The width of the AIR field can be set using the click-in plastic cover in front of the detector’s lens.

1. Slide

2. Push & click!

Possible settings (Dimensions at 2.2 m mounting hight):

Detector without cover:

All light beams are active

Field width:

2.3 m x 0.2 m

at 2.2 m

Reviews: