Bircher Reglomat Swissdoor ENT-R Assembly Instructions Download Page 4

Mounting the rubber profile 

4.2

Moisten «click-fit foot» rubber profiles with a solution of soapy water and press into the 

aluminium profile (do not pull in). 

To ensure correct functioning of safety edges with a click-fit foot, after moun-

ting, the safety edge must be pressed in along its entire length to make sure 

the foot engages properly in the aluminium bar.

Otherwise, the safety edge will connect through. Check fit of rubber profile in 

aluminium strip.

2

2

Final checks

4.3

Check the resistance of the safety edge with an ohmmeter.  

Notice:

 The overall safety of the machine and its protection systems  

depends on the quality, reliability and correct connection of the inter-

faces. 

Warning: Perform a final functional and visual check of the safety edge. Once mounting is complete, test the safety edge on  

the object to make sure it functions correctly. The protection system must also satisfy the force, overtravel and sensitivity  

requirements of the standards applicable in the relevant country.

The safety edge is maintenance-free. If damage occurs, such as a brittle or torn rubber profile, non-tight switching chamber, 

insufficient contact  

resistance in the activated state (>500 ohms)

 or similar, the safety edge must be replaced immediately. Please request a new one, remembering  

to state the product designation. 
Check the resistance of the safety edge with an ohmmeter, referring to the table above. 

Maintenance 

5

6

Contact details

Manufacturer

Bircher Reglomat AG

Wiesengasse 20

CH-8222 Beringen

www.bircher-reglomat.com

Press in profile at both ends 
Work from outside inwards

Glueing on the end caps 

3.3

ES-KLEBER

Attach end caps by applying ES-KLEBER to the points shown and hold in place, applying pressure across the whole area, for approx. 10 seconds. 

Note:

 No end caps on ELE040/081 and ELE040/105

Attaching aluminium strip 

4.1

Attach aluminium strip to object with 

countersunk head screws.

 Recommended hole  

spacing 300 mm. Make sure aluminium strip is securely attached to ends of safety edge.  

You may have to make holes for the cable to exit. 

NB:

 In the case of 2-panel systems, the two profiles should be aligned facing each other.  

The same applies to any counter sealing profile. 

Notice:

 If possible, avoid routing the cable through the aluminium profile as it may press 

against the switching chamber. 

T-foot rubber profiles should be pulled into the aluminium. 

Any burrs on the aluminium profile must be removed first. 

End pieces

ENEH-8  

ENES-8

ENEH-0

ENES-0

ENEH-K...

ENES-K...

8.1 - 8.5 kΩ

< 500 Ω

< 500 Ω

< 500 Ω

Mounting the safety edge

4

c

c

Glue