Technical data

Technology

:   

Active infrared, 40 kHz

Operating temperature:  -20°C to 40°C

6

Status

Display

Beeper function

(if turned on - see section 4.2)

No Safety curtain spot detected

Green

No beeping   

Safety curtain spot detected

Red

Constant beeping

Declaration of conformity

7

Bircher Reglomat 

870 Pratt Avenue N
Schaumburg, IL 60193

Phone: 

847-952-3730

Toll-Free:

800-252-1272

Fax: 

847-952-2005

Email: 

[email protected]

Web: 

www.bircherreglomat.com

Manufacturer: 

Bircher Reglomat AG,  Wiesengasse 20, CH-8222 Beringen, Switzerland, www.bircher-reglomat.com

Importer:

Bircher America, Inc. 870 Pratt Ave N, Schaumburg, IL 60193, USA, www.bircherreglomat.com

Standards taken into account:   

EN 61000-6-2, EN 61000-6-3

Important note:

Bircher Reglomat reserves the right to change any information in this document without notice. 
For the latest version, please visit www.bircherreglomat.com or call 800-252-1272 to request a copy.

 

 

 

Use sensor scan mode to determine available sensor addresses. 

Use the 2” width mark on the RC Duo 2 to determine e.g. when the infrared

safety curtain is 2” from the face of a sliding door. 

2” (5 cm)

Beeper function

4.2

LED

Green

Red

On Continuously 

Idle

Safety curtain spot detected

Blinking

Low battery

Safety curtain spot detected AND 

low battery

BEEPER ON:

Press and hold   

B

for 2 seconds

BEEPER OFF*

:

Press and hold   

B

for 2 seconds

Remote must be turned on to access beeper function

*Beeper function turns off when remote turns off. This setting must be 

re-activated each time the remote is turned on. 

Sensor scan mode

4.3

LED indicator 

4.1

Safety curtain spot detector

4.4

Additional functions

4

Max. air humidity

:  

90%, non-condensing

Batteries

3 AAA (1.5 V) batteries

Press  

F

for 

2 seconds

to

enter sensor scan mode.  

All addresses assigned to

sensors in proximity are illu-

minated on the keypad.  

The active address is now 

illuminated on the keypad.  

Select the corresponding ad-

dress to establish communi-

cation with a specific sensor.   

Safety instructions

5

Only use this remote for it’s intended purpose. 

Do not point the IR beam towards your eyes or those of others! 

Observe all national and international door safety regulations. 

Only trained, qualified personnel may install sensors. 

This unit may only be opened and repaired by Bircher Reglomat. 

Always consider the safety functions of your application as a whole, never just in relation to one individual section of the system. 

The installer is responsible for carrying out a risk assessment and installing sensors and door systems correctly.