Safety instructions

1

Installation, mounting

2

2.1

Quality

 

international
 

level

EN ISO
9001

– This unit may only be operated from a protection low-voltage system with electrical separation.
– The unit may only be commissioned by trained and qualified personnel.
– Operation other than as described in these instructions is contrary to the designated use and is therefore prohibited.
– Please note all operating parameters (technical data).
– Do not open or repair the unit yourself, this will invalidate all warranty and guarantee claims, and may even endanger yourself

and other people.

– Never touch any electronic components of the detector because this can lead to defects.
– Only use the supplied cable to connect the detector.
– This product is not allowed to be used as a presence detector.

Mounting location

Electrical connection

3

Opening the detector requires a screwdriver with a blade approx. 4 mm wide (not supplied).

Microwave Motion Detector
as an Opening Sensor for Automatic Doors

Detector

Controller

white

brown

green

yellow

white

Power
Supply

Potential-
free
output

12–36 V DC /
12–28 V AC

GND

+

Controller input

brown

green

yellow

Cable

Detector

Controller

white

brown

green

yellow

white

Power
Supply

Potential-
free
output

12–36 V DC/
12–28 V AC

GND

Controller input

brown

green

yellow

Cable

+

High Active:

Connect the yellow wire to the input, the green wire to

the supply voltage of the door controller.

Low Active:

Connect the yellow wire to GND, the green wire to

the input of the door controller.

Low Active

High Active

Easy

Motion

Operating Instructions

Please keep for future reference!

2.2

2.3

2.4

Drilling jig

Opening the housing

Cable entry into the housing

Wall mounting

Use the drilling jig included in delivery.

In mounted state

In unmounted state

Feed the connection cable through
the provided cutout and connect.

– The detector must not be obscured by covers or signs.
– The detector must be protected from precipitation (rain, snow) when

installed outdoors (if possible, mount far under the roof or, if need be,
use the rain protection cover EasyMotion Cap).

– Avoid exposing the detector to vibrations.
– Fluorescent tubes should not be placed in the immediate vicinity of the

detection area.

– Ceiling mounting: For distances

10 cm to the door, use the ceiling mounting bracket EasyMotion Holder,

For distances

30 cm to the door, the detector can be mounted directly to the ceiling.

Summary of Contents for EasyMotion

Page 1: ...für automatische Türen Sensor Steuerung weiss braun grün gelb weiss Power Supply Potential freier Ausgang 12 36 V DC 12 28 V AC GND Eingang Steuerung braun grün gelb Kabel Sensor Steuerung weiss braun grün gelb weiss Power Supply Potential freier Ausgang 12 36 V DC 12 28 V AC GND Eingang Steuerung braun grün gelb Kabel High Active Anschliessen der gelben Ader an den Eingang die grüne Ader an die V...

Page 2: ...dlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinien 1999 5 EG und 89 336 EWG befindet Die vollständige Konformitätserklärung steht auf unserer Internetseite zur Verfügung Einstellbarer Bereich 25 45 in 5 Schritten Achtung 0 an der Anzeige entspricht 25 Feldgrösse bei 2 2 m 40 Min 0 8 m x 1 6 m Tx B Max 2 3 m x 4 8 m Tx B 0 5 1 1 5 2 2 2 1 5 1 0 5 0 0 5 1 1 5 Maximum Min...

Page 3: ...n yellow white Power Supply Potential free output 12 36 V DC 12 28 V AC GND Controller input brown green yellow Cable Detector Controller white brown green yellow white Power Supply Potential free output 12 36 V DC 12 28 V AC GND Controller input brown green yellow Cable High Active Connect the yellow wire to the input the green wire to the supply voltage of the door controller Low Active Connect ...

Page 4: ...e basic requirements and the other relevant provisions of the standards 1999 5 EC and 89 336 EEC The complete declaration of conformity is available on our Internet site Adjustable range 25 45 in steps of 5 Important 0 on the display corresponds to 25 Field dimensions for 2 2 m 40 Min 0 8 m x 1 6 m D x W Max 2 3 m x 4 8 m D x W 0 5 1 1 5 2 2 2 1 5 1 0 5 0 0 5 1 1 5 Maximum Minimum Troubleshooting ...

Reviews: