Safety instructions
1
Installation, mounting
2
2.1
Quality
international
level
EN ISO
9001
– This unit may only be operated from a protection low-voltage system with electrical separation.
– The unit may only be commissioned by trained and qualified personnel.
– Operation other than as described in these instructions is contrary to the designated use and is therefore prohibited.
– Please note all operating parameters (technical data).
– Do not open or repair the unit yourself, this will invalidate all warranty and guarantee claims, and may even endanger yourself
and other people.
– Never touch any electronic components of the detector because this can lead to defects.
– Only use the supplied cable to connect the detector.
– This product is not allowed to be used as a presence detector.
Mounting location
Electrical connection
3
Opening the detector requires a screwdriver with a blade approx. 4 mm wide (not supplied).
Microwave Motion Detector
as an Opening Sensor for Automatic Doors
Detector
Controller
white
brown
green
yellow
white
Power
Supply
Potential-
free
output
12–36 V DC /
12–28 V AC
GND
+
Controller input
brown
green
yellow
Cable
Detector
Controller
white
brown
green
yellow
white
Power
Supply
Potential-
free
output
12–36 V DC/
12–28 V AC
GND
Controller input
brown
green
yellow
Cable
+
High Active:
Connect the yellow wire to the input, the green wire to
the supply voltage of the door controller.
Low Active:
Connect the yellow wire to GND, the green wire to
the input of the door controller.
Low Active
High Active
Easy
Motion
Operating Instructions
Please keep for future reference!
2.2
2.3
2.4
Drilling jig
Opening the housing
Cable entry into the housing
Wall mounting
Use the drilling jig included in delivery.
In mounted state
In unmounted state
Feed the connection cable through
the provided cutout and connect.
– The detector must not be obscured by covers or signs.
– The detector must be protected from precipitation (rain, snow) when
installed outdoors (if possible, mount far under the roof or, if need be,
use the rain protection cover EasyMotion Cap).
– Avoid exposing the detector to vibrations.
– Fluorescent tubes should not be placed in the immediate vicinity of the
detection area.
– Ceiling mounting: For distances
≥
10 cm to the door, use the ceiling mounting bracket EasyMotion Holder,
For distances
≥
30 cm to the door, the detector can be mounted directly to the ceiling.