5.2.6

 

Interleaved 2 of 5 

Restore Factory Defaults 

 

Restore the Factory Defaults of Interleaved 2 of 5 (default) 

 

Enable/Disable Interleaved 2 of 5 

 

 

Enable Interleaved 2 of 5 (default) 

Disable Interleaved 2 of 5 

 

M

essage Length

 

Message length can be set to the maximum value, minimum value. The data between the maximum and the 

minimum is valid. 

The maximum value and minimum value can be set using Programming Command. Please check the 

programming command guide for the detail. 

Interleaved 2 of 5 max length command: 020404. The parameter of this command can be set from min to 80. 

Interleaved 2 of 5 min length command: 020403. The parameter of this command can be set from 2 to max. 

Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25. 

Programming command 

Max: 02040425. 

Min: 02040310. 

 

Interleaved 2 of 5 Check Digit 

 

 

 

No check Char (default) 

Validate and Transmit 

Validate not Transmit 

Summary of Contents for FD-011WU

Page 1: ...2D Barcode Reader User Guide V1 6CC FD 011WU...

Page 2: ...ration 6 3 1 Trigger Mode 6 3 2 Presentation Mode 6 3 3 Cell Phone Mode 7 3 4 Inverse color 8 3 5 Illumination for Trigger Mode 8 3 6 Illumination for Presentation Mode 8 3 7 Beeper Good Read 10 3 8 B...

Page 3: ...2 9 Code 39 29 5 2 10 Coda bar 31 5 2 11 Code 93 33 5 2 12 GS1 128 34 5 2 13 MSI 35 5 3 2D Symbologies 37 5 3 1 PDF 417 37 5 3 2 Micro PDF 417 38 5 3 3 QR Code 39 5 3 4 Data Matrix 40 5 3 5 Maxi code...

Page 4: ...1 1 Getting Started 1 1 Factory Defaults Scanning the following barcode can restore the FD 011WU to the factory defaults Note Use this feature with discretion Restore All Factory Defaults...

Page 5: ...vice like PC POS However to ensure smooth communication and accuracy of data you need to set communication parameters including baud rate parity check data bit and stop bit to match the host device Th...

Page 6: ...3 2 2 Baud Rate Baud rate is the number of bits of data transmitted per second Set the baud rate to match the Host requirements 2400 4800 9600 19200 38400 57600 115200 default...

Page 7: ...nection you can enable the USB HID KB feature by scanning the barcode below Then scanner transmission will be simulated as USB keyboard input The Host receives keystrokes on the virtual keyboard It wo...

Page 8: ...to Lower Case Example When the Convert All to Lower Case feature is enabled barcode data AbC is transmitted as abc 2 7 USB COM Port Emulation If you connect the engine to the Host via a USB connectio...

Page 9: ...a serial trigger command When in manual trigger mode the scanner scans until a barcode is read or until the hardware trigger is released When in serial mode the scanner scans until a barcode has been...

Page 10: ...pturing image and illumination session If you want to enable Cell Phone reading in Trigger Mode please scan below barcode Trigger Mode with Cell Phone reading If you want to enable Cell Phone reading...

Page 11: ...n 3 5 Illumination for Trigger Mode Illumination setting for Trigger Mode High Level Illumination default Mid Level Illumination 1 Mid Level Illumination 2 Low Level Illumination Illumination OFF 3 6...

Page 12: ...vel Illumination 1 Mid Level Illumination 2 Low Level Illumination Illumination OFF Illumination setting when in Idle High Level Illumination Mid Level Illumination 1 Mid Level Illumination 2 Low Leve...

Page 13: ...10 3 7 Beeper Good Read On default Off 3 8 Beeper Tone Good Read Low Middle High default 3 9 Beeper Duration Good Read Normal default Short 3 10 Beeper Number Good Read 1 default 2 3 4...

Page 14: ...11 5 6 3 11 Barcode Scanning Delay No Delay default Delay 500MS Delay 2000ms...

Page 15: ...12 4 Data Formatting 4 1 General Configuration Add CR Add LF Add CRLF Add TAB...

Page 16: ...exadecimal values of a desired prefix and then scan the Save barcode Refer to Appendix 2 ASCII Table for hexadecimal values of characters Example Set the custom Prefix to ODE 1 Check the hex values of...

Page 17: ...fix and then scan the Save barcode Refer to Appendix 4 ASCII Table for hexadecimal values of characters Example Set the custom Suffix to ODE 1 Check the hex values of ODE in the ASCII Table ODE 4F 44...

Page 18: ...ttings Enable Disable All Symbologies If the Disable All Symbologies feature is enabled the engine will not be able to read any non programming barcodes except the programming barcodes Enable All Symb...

Page 19: ...ximum and the minimum is valid The maximum value and minimum value can be set using Programming Command Please check the programming command guide for the detail Code 128 max length command 020A03 The...

Page 20: ...the last one as its check digit used to verify the accuracy of the data Transmit EAN 8 Check Digit default Do Not Transmit EAN 8 Check Digit Add On Code An EAN 8 barcode can be augmented with a two d...

Page 21: ...efault Add On Code Required EAN 8 Add On Code Required EAN 8 Add On Code Not Required default ENA JAN 8 Addenda Separator When this feature is enabled there is a space between barcode and addenda When...

Page 22: ...ble EAN 13 Enable EAN 13 default Disable EAN 13 Transmit Check Digit Transmit EAN 13 Check Digit default Do Not Transmit EAN 13 Check Digit Add On Code Enable 2 Digit Add On Code Disable 2 Digit Add O...

Page 23: ...between barcode and addenda When this feature is disabled there is no space Enable ENA JAN 13 Addenda Separator default Disable ENA JAN 13 Addenda Separator ISBN Translate When enable this feature an...

Page 24: ...efaults Restore the Factory Defaults of UPC E default Enable Disable UPC E0 E1 Enable UPC E0 default Disable UPC E0 Enable UPC E1 default Disable UPC E1 UPCE0 Check Digit Enable UPC E0 Check Digit def...

Page 25: ...E barcodes that have addenda Enable UPC E0 Required Disable UPC E0 Required default UPCE0 Addenda Separator Enable UPC E0 Separator default Disable UPC E0 Separator UPCE0 Number System The number sys...

Page 26: ...23 UPCE0 Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda default Enable 5 Digit Addenda Disable 5 Digit Addenda default...

Page 27: ...le Disable UPC A Enable UPC A default Disable UPC A UPC A Check Digit Enable UPC A Check Digit default Disable UPC A Check Digit UPC A Addenda Required When required is scanned the scanner will only r...

Page 28: ...digit of UPC symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will be not transmitted Enable UPC A Number System default Disable UPC A Number Sy...

Page 29: ...lue and minimum value can be set using Programming Command Please check the programming command guide for the detail Interleaved 2 of 5 max length command 020404 The parameter of this command can be s...

Page 30: ...the maximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Matrix 2 of 5 max length command 020803 T...

Page 31: ...tween the maximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Industrial 2 of 5 max length comman...

Page 32: ...Enable Code 39 default Disable Code 39 Transmit Start Stop Character Transmit Start Stop Character Do not Transmit Start Stop Character default Code 39 Check Character No Check Char default Validate a...

Page 33: ...gramming command Please check the programming command guide for the detail Code 39 max length command 020308 The parameter of this command can be set from min to 48 Code 39 min length command 020307 T...

Page 34: ...he minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Coda bar max length command 020206 The parameter...

Page 35: ...32 Transmit Start Stop Character Transmit Start Stop Character Do not Transmit Start Stop Character default Coda bar Check Character No Check Char default Validate and Transmit Validate no Transmit...

Page 36: ...e minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Code 93 max length command 020D03 The parameter of...

Page 37: ...e minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail GS1 128 max length command 020B03 The parameter of...

Page 38: ...the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail MSI max length command 020E04 The parameter of this comm...

Page 39: ...it Default Validate Type 10 Transmit Validate 2 Type 10 Characters No Transmit Validate 2 Type 10 Characters Transmit Validate Type 11 Then Type 10 Character No Transmit Validate Type 11 Then Type 10...

Page 40: ...the maximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail PDF417 max length command 021F06 The para...

Page 41: ...he maximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail PDF417 max length command 022003 The param...

Page 42: ...m and the minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail QR max length command 023703 The parameter...

Page 43: ...aximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Data Matrix max length command 023603 The para...

Page 44: ...imum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Maxi Code max length command 023403 The paramete...

Page 45: ...d the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Aztec max length command 023306 The parameter of this c...

Page 46: ...and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Hanxin max length command 023803 The parameter of thi...

Page 47: ...l Symbologies 5 4 1 China Postal Code Restore Factory Defaults Restore the Factory Defaults of China Postal Code default Enable Disable China Postal Code Enable China Postal Code Disable China Postal...

Page 48: ...45 5 4 2 Telepen Restore Factory Defaults Restore the Factory Defaults of Telepen default Enable Disable Telepen Enable Telepen Disable Telepen default...

Page 49: ...ical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Con...

Page 50: ...Single Quote 28 40 Right Closing Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52...

Page 51: ...0 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Bac...

Page 52: ...67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 Left Opening...

Page 53: ...50 6 2 Appendix 2 Digit Barcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F...

Reviews: