11. Specifications
Supply voltage:
1
×
230 V +6/-10%, 50 Hz
Motor protection:
No external motor protection is necessary
Degree of protection:
IP 44
Winding class:
Classe d’isolation F
Temperature class:
TF 110
Ambient temperature:
max. 40 °C
Media temperature:
+15 °C to 95 °C
The temperature of the medium must be higher
than the ambient temperature to prevent condensation water
from forming in the terminal box and the stator.
up to 75 °C water temperature
0,05 bar
at 90 °C water temperature
0,30 bar
at 110 °C water temperature
1,10 bar
For every ±100 m altitude ±0,01 bar
Pression de service nécessaire:
10 bar
Noise:
sound pressure level under 54 dB(A)
Leakage current:
The power line filter of the pump causes a leakage current
to the ground wire of less than 3.5 mA during operation.
Minimum pressure
at 500m altitude:
Ambient temperature
Media temperature
°C
Min. °C
Max. °C
15
15
110
30
30
110
35
35
90
40
40
70
12. Disposal
This product and the special electronic components (lead-free)
must be disposed of in accordance with the environmental
regulations.
It is recommended to keep the temperature
below 65 °C in drinking water installations
to prevent the danger of lime deposits.