DETAIL DOOR
For storage quantities ≤ 15,000 kg, there are no fire
protection requirements for doors or hatches to the pellet
store. Doors and hatches must open outwards and be
fitted with a circumferential seal (dust-tight). For doors or
hatches to the pellet store, wooden boards must be fitted
on the inside to relieve pressure so that the pellets do not
press against the door or hatch. The door handle must be
removed from the inside. The door lock must be sealed
dust-tight from the inside.
ATTENTION:
Observe country-specific regulations!
DETAIL IMPACT PROTECTION MAT
The impact protection mat protects the pellets from breaking when they hit the storage room wall. Furthermore,
the wall itself is protected from damage. The impact protection mat consists of an abrasion-resistant and ageing-
resistant plastic with a fastening option for ceiling mounting and a downward tensioning option (trampoline
effect). It is mounted opposite the filling spout with a wall clearance of at least 300 mm.
6.5
FLOOR PLAN/SECTION PELLET STORAGE ROOM
06
PELLET STORAGE ROOM
Door
(see detailed view)
Screw discharge
Inlet & outlet spigots
Storz “A“
min. 500
min. 300
min. 200