PV-WM Installation Guide v1.2|10.2018|en
2.
Installation
Cable types
№
Cable connection
Max. length
Type
1
Ethernet (IEEE 802.3)
100 m.
Four twisted pair cables of no lower than category five
with a wire size of no less than 0.2 mm
2
2
Power source
50 m.
Duplex cable with a wire size of no less than 0.75 mm
2
(for
example, 3192Y)
General installation notes
Install the reader on vertical surface;
Cables must be installed in accordance with the operational code for electrical
installations;
Do not lay cables within 30 cm of sources of electromagnetic interference;
All cables must only intersect power cables at a right angle;
All cable extensions must be soldered.
Carefully check for mechanical damage on the surface of the reader circuit board and case;
In order to avoid short circuits, the protected ends of cables used to connect the reader
must not exceed 5 mm.
Mounting on wall
1.
Decide where to install reader, using a mounting template.
2.
Drill holes, according to a mounting template and insert dowels inside the holes.
3.
Place metal plate on wall and fix it with self-tapping screws.
4.
Put cables through back cover cable input.
5.
Attach the cover to reader and fix it with four mounting screws.
6.
Connect cables according to p.2.4-2.5.
7.
Attach reader to the plate and fix the retaining screws.