C
O N C E P T S O F
O
P E R A T I O N
32
© Copyright 2002, Bioscrypt Inc. All rights reserved.
12
Select the appropriate baud rate from the
Host Port Baud Rate
drop
down list (9600 is recommended). Keep in mind that you are currently
talking over the AUX port, but you are changing the Host Port settings
that will be used when you connect to the unit through the Host Port
wires on the back of the unit.
13
Set the
Host Port Protocol
to RS-485 if you will be using a networked
environment. Alternatively you may choose RS-232 if you will not be
networking the VeriProx. Remember that the RS-232 and RS-485
connections are made through different wires on the pigtail. (Consult
the installation guide).
Make sure that the Network IDs in the UNITIDS.DAT file match those assigned to
the readers. If not, update accordingly.