Summary of Contents for BS-050102-AAF

Page 1: ......

Page 2: ...e would like to hear from you Please send all feedback to Manufacturer SIA Biosan R tsupites iela 7 k 2 R ga LV 1067 Latvija Latvia Phone 371 674 261 37 Fax 371 674 281 01 www biosan lv Service e mail...

Page 3: ...aintenance 13 10 Storage and transportation 13 11 Warranty 14 12 EU Declaration of conformity 15 1 About this edition of user instructions The current edition of the user instructions applies to the f...

Page 4: ...th this product Ensure that the power plug is easily accessible during use Disconnect the unit from the mains before moving If liquid penetrates into the unit disconnect it from the mains and have it...

Page 5: ...operation Do not operate the unit in environments with aggressive or explosive chemical mix tures Please contact manufacturer for possible operation of the unit in specific at mospheres Do not operate...

Page 6: ...6 0 McF range if necessary We reccommend using our Biosan standards for opyimal results but both commercial standards and the cell suspensions prepared in the laboratory e g BaSO4 can be used for cal...

Page 7: ...om below 4 3 Setup for DEN 1B Battery installation Pull back the pin on the battery compartment fig 1 2 on the underside and open lid Insert batteries as shown on the scheme inside and close the lid P...

Page 8: ...n the working mode If flat bottomed tubes are used the solution level should be higher than 7 mm from a tube bottom if round bottomed tubes are used higher than 12 mm from a tube bot tom Check if the...

Page 9: ...5 4 Shake the tube with the solution It is recommended to use a vortex for shaking e g Biosan V 1 plus 5 5 To ensure measurement precision check the external diameter of tubes By default the unit work...

Page 10: ...1B can operate without external power supply on battery power Caution Make sure that the tube socket is empty For 12 mm or 16 mm tubes place the A 12 or A 16 adapters accordingly 6 5 Press the Select...

Page 11: ...mode and the socket of the unit is empty Press and hold Install key for 5 seconds The unit displays a dot then changes it to The values are now reset 6 11 Switch off the unit using the Power switch p...

Page 12: ...es Description Catalogue number A 12 adapter for 12 mm tubes BS 050102 IK CKG16 calibration kit for 16 mm glass tubes Latex particles BS 050102 BK Calibration kit for 12 mm glass tubes Polymer particl...

Page 13: ...ic parts use 75 ethanol or DNA RNA removing solution e g Biosan PDS 250 After disinfecting it is necessary to wipe the surfaces dry 9 2 3 Internal optical parts Do not use liquids to clean optical par...

Page 14: ...B the Premium class model one year of extended warranty is available free of charge after registration during 6 months from the date of sale Online regis tration form can be found in section Warranty...

Page 15: ...cal equipment for measurement control and laboratory use General requirements EMC 2014 30 EU LVS EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Genera...

Page 16: ...Biosan SIA R tsupites iela 7 k 2 R ga LV 1067 Latvija Latvia Phone 371 67426137 Fax 371 67428101 http www biosan lv Edition 3 01 May of 2021...