FOTS100 User Manual 

 

© Opsens Inc. 

IMP0023 Pico-M Manual rev 2.1 test.doc 

MENU

LOG

2. Local Operation 

2.1  Keyboard 

MENU

LOG

 

 
 

2.1.1  Switch on/off 

The FOTS100 is switched on/off with this button. 
 

2.1.2  Menu Button 

Menu button gives access to the system menus. Once in the menu, this button 

brings the user one level higher into the menu hierarchy. Once at the root, the 

system will exit the menu and goes back to measurement display. 

2.1.3  Left/Right Arrows 

Left/Right arrows allow moving from one digit to the other when a value is 

being entered.  

2.1.4  Up/Down Arrows 

Up/Down arrows allow navigating 1)  between menu items of a given 

hierarchical level, or 2) it allows changing a value being entered. 

 

2.1.5  Confirmation button 

Confirmation button permits confirming 1) a new value being entered, 2) 

confirm the selection of a menu item then moving one hierarchical level lower, 

3) refreshing displayed value in the case of diagnostic. 

2.1.6  Log button 

(Reserved for future use) 

 

 

2.2  System Setting 

The functions below are used to setup specific parameters of the FOTS100. 

2.2.1  Averaging mode 

The user can set ON  or  OFF  the averaging mode  (ON by default). When on, the 

measurements either displayed on the front panel display, output on the analog output or 

on the RS-232 port is the result of the average of twenty  sequential measurements 

Summary of Contents for Opsens FOTS100

Page 1: ...FOTS100 User Manual Opsens Inc IMP0023 Pico M Manual rev 2 1 test doc 1 FOTS100 User Manual BIOPAC Systems Inc 42 Aero Camino Goleta CA 93117 Tel 805 685 0066 Fax 805 685 0067 WWW BIOPAC COM...

Page 2: ...le for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material This warranty does not apply to the transducers sold for...

Page 3: ...OSION PROOF Installation of this instrument in an area requiring devices rated as intrinsically safe is not recommended WARNING VOLTAGE SUPPLY Use only the wall plug in power supply delivered with you...

Page 4: ...1 2 Menu Button 7 2 1 3 Left Right Arrows 7 2 1 4 Up Down Arrows 7 2 1 5 Confirmation button 7 2 1 6 Log button 7 2 2 System Setting 7 2 2 1 Averaging mode 7 2 2 2 Analog output 8 2 2 3 Units 8 2 3 S...

Page 5: ...namely the OTG M series The fiber optic connector provided with the OTG M sensors is a ST type connector Remove the protective cap of the FOTS100 ST mating and engage the sensor connector with the ori...

Page 6: ...0 is ready to measure temperature The display shows the temperature measurements with a refreshing rate of three readings per second The measurement readings are also available at the analog output an...

Page 7: ...s Up Down arrows allow navigating 1 between menu items of a given hierarchical level or 2 it allows changing a value being entered 2 1 5 Confirmation button Confirmation button permits confirming 1 a...

Page 8: ...Temperature Voltage output x 10 C V 5 C The default value of the scale factor is 50 C V or its equivalent in F and the default value of the offset is 0 C or its equivalent in F NOTE The analog output...

Page 9: ...r is connected to the unit take note of the diagnostic parameters and contact BIOPAC technical support During a No Signal condition the analog output and the serial ports output constant values as fol...

Page 10: ...ens Inc IMP0023 Pico M Manual rev 2 1 test doc 10 2 4 Setting the averaging measurements Menus levels Figure 3 Averaging measurements Averaging twenty sequential measurements are averaged for obtainin...

Page 11: ...nual Opsens Inc IMP0023 Pico M Manual rev 2 1 test doc 11 2 5 Setting the analog output Menus levels Figure 4 Setting up the analog output Both the scale factor and offset can be setup according to us...

Page 12: ...al Opsens Inc IMP0023 Pico M Manual rev 2 1 test doc 12 2 6 Setting the temperature units Menus levels Figure 5 Setting the temperature units The temperature units can be set to degree Celsius or to d...

Page 13: ...igure 6 Diagnostic The user can look through a variety of diagnostic parameters for diagnosing potential problem with the FOTS100 or the fiber optic sensor The available diagnostic parameters are as f...

Page 14: ...commands available for the FOTS100 But for ease of operation Opsens provides its own control software called SoftSens which gives access to all the functionalities of the FOTS100 conditioner See Soft...

Page 15: ...available Resolution 0 C Sampling rate 50 Hz 20 ms Output interface Display 5 Volts and RS 232 standard Communication protocol SCPI default Input power 9 to 24 VDC positive is center pin 12 V AC DC wa...

Reviews: