Notification obligation

Your BIONEST

®

 treatment system is equipped with an alarm; should the alarm 

emit a signal, contact Bionest immediately.

Furthermore, for the warranty to remain valid, the client must immediately 
notify Bionest of any apparent abnormality or malfunction. Failure to advise 
Bionest within reasonable delay may void the warranty.

Bionest agrees to assess the situation and make necessary corrections, 
if required, within reasonable delay of notification, if the present warranty 
conditions are applicable.

The client must allow access to the septic installation to any Bionest 
representative at all times.

Exclusions

Not included in the present warranty are the following damages or problems:

Any damage or problem caused by a fortuitous event or an « Act of God » , 
such as, without limiting the generality of the preceding, earthquakes, floods, 
freezing, hurricanes, landslides, explosions or dynamiting.

Any damage or problem caused by the fault or act of a third party.

Any damage or problem arising from an installation, modification, correction or 
addition carried out by a person not authorized by Bionest.

Any damage or problem arising from an installation, modification, correction or 
addition to the wastewater treatment system carried out after the installation 
of the BIONEST

®

 system, without Bionest’s written approval.

Any damage or problem caused by the use of a primary treatment non 
compliant to applicable regulation requirements in effect.

Any damage or problem, if it is proven that the BIONEST

®

 system was not used 

according the terms and conditions of the Owner’s manual.

Any damage or problem, if the maintenance of the BIONEST

®

 system was not 

performed according to Bionest recommendations.

Any damage or problem caused by the fault or action of the client or the client’s 
successors including, but without limiting the generality of the preceding, 
refusing access to the system for inspection purposes.

Any damage, problem or work required to access the BIONEST

®

 system which, 

under normal conditions, does not require any special action, including, but 
without limiting the generality of the preceding, excavation, snow removal or 
demolition.

Summary of Contents for ZENITH BST-1250

Page 1: ...BIONEST ZENITHTM Owner s manual...

Page 2: ...K8A 7G8 Tel 613 735 5203 Toll free 1 866 477 5203 Fax 613 732 1881 inquiry on bionest ca www bionest ca Head office 55 12th Street Shawinigan Quebec G9T 5K7 Tel 819 538 5662 Toll free 1 866 538 5662...

Page 3: ...DOC0050 2020 01 14 3 TABLE OF CONTENTS OPERATING PRINCIPES 4 MODEL DESIGNATION 5 COMPONENTS 6 IMPORTANT OPERATING INSTRUCTIONS 7 WHAT TO DO IF 9 SEASONAL AND INTERMITTENT USE 10 MAINTENANCE 10 Appendi...

Page 4: ...robic biological culture fixed on a self supported synthetic support called BIONEST media Primary treatment collects wastewater and clarifies it by naturally separating solids and fat by settling and...

Page 5: ...his range adapts to all field configurations regardless of the type of soil The next table shows the required model according to the daily flow rate of an isolated dwelling Residential and other build...

Page 6: ...fuser is installed in the BIONEST reactor The length of the diffuser varies depending on model 3 4 Air pump The air pump provides oxygen to the system continuously The continuous aeration allows to ma...

Page 7: ...mp is not operating may result in external odors clogging of the polishing field and warranty cancellation In order to ensure proper and efficient functioning of your BIONEST wastewater treatment syst...

Page 8: ...than 3 m from your septic installation To build a permanent installation over the septic installation unless it has a 1 75 m minimum height clearance Any contact with wastewaters constitutes a biologi...

Page 9: ...quate vent I make sure the building is equipped with an adequate functional unclogged and undamaged vent I contact Bionest I notice a backflow Home plumbing or effluent filter is clogged or primary tr...

Page 10: ...responsibility to provide quick and easy access to all covers upon interventions 7 1 Emptying Primary treatment such as the septic tank should be cleaned when sludge and or scum accumulation represen...

Page 11: ...more frequent cleaning by the Owner may become necessary a clogged filter may cause overheating or pump failure 7 3 2 Alarm Your BIONEST treatment system is equipped with a visual and audible alarm l...

Page 12: ...BTT 2750 BTT 3400 BTT 3900 BTT 4900 BTT 6250 BTT 8900 BTT 10000 BST 1250 BST 1700 BST 2100 BST 2600 Media TWENTY 20 years Parts and components TWO 2 years Periodic replacement parts ONE 1 year Periodi...

Page 13: ...t or act of a third party Any damage or problem arising from an installation modification correction or addition carried out by a person not authorized by Bionest Any damage or problem arising from an...

Page 14: ...as null and void Bionest will thus be considered as completely discharged from all obligations under this warranty Indemnities and damages The liability and obligations of Bionest under this warranty...

Page 15: ...il and shall be considered null and void Inspection The client or the client s successors shall allow any Bionest representative to perform all necessary monitoring and or inspection measures when dee...

Page 16: ...the terms and conditions of this warranty shall continue to apply to the purchaser and or the client s successors and have full effect until the end of the warranty period Jurisdiction The parties ack...

Page 17: ...BIONEST ZENITHTM Owner s manual DOC0050 2020 01 14 17 8 APPENDIX INSTALLATION SPECIFICATION...

Page 18: ...e m 3 BIONEST reactor Minimal treatment volume m 3 Air pump s Number Model BST MODELS BST 1250 1 250 1 3 2 6 1 HP 60 BST 1700 1 700 1 7 3 5 1 HP 80 BST 2100 2 100 2 1 4 3 1 HP 80 BST 2600 2 600 2 6 5...

Page 19: ...of any joint or any other opening The BIONEST system is equipped with an alarm to detect a malfunction of the aeration Please refer to the manufacturer s installation specifications to install this co...

Reviews: