background image

4

3

The length of cord used on this appliance was selected to reduce 

the hazards of becoming tangled in, or tripping over a longer cord. 

If a longer cord is necessary an approved extension cord may be used. 

The electrical rating of the extension cord must be equal to or greater

than the rating of the humidifier. Care must be taken to arrange the

extension cord so that it will not drape over the countertop or tabletop

where it can be pulled on by children or accidentally tripped over.

HOW YOUR COOL MOISTURE HUMIDIFIER WORKS

Your Bionaire

®

Cool Moisture humidifier draws dry air through the rear

air intake grill area. This air is then passed through a moisture–laden

wick filter which retains the minerals and deposits. The resulting moist

air is directed back into the room from the top air grill.

☛ 

Tip: This humidification system provides a cool, invisible moisture

output. It is normal not to see the mist.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is switched off and disconnected from 

the electrical outlet.

2. Select a location for your

humidifier, on a flat surface,

about 4" away from the wall.

Do not place your humidifier 

on furniture, a floor location

that will not be damaged by 

moisture is best.

3. Remove the water reservoir, 

by holding the reservoir handle

and lifting straight upwards.

4. Remove the humidifier housing by holding the housing support 

handle and lifting straight upwards. Check to see that the wick 

filter is properly in place. Replace the humidifier housing.

FILLING THE WATER RESERVOIR

5. Twist off the water reservoir cap located on the bottom of the 

water reservoir by turning counter clockwise and fill the water 

reservoir with cool, fresh water. Do not fill with warm water as 

this may cause leaking.

6. After filling the water reservoir, replace the water reservoir cap by

firmly turning clockwise and then replace the water reservoir on 

the base. The water reservoir will immediately begin to empty into 

the base.

mode

refill

humidistat

power

Humidifier
Housing

Float 
(underneath)

Moisture
Outlet

Control
Panel

Wick
Filter

Base

Figure 1

Housing
Support Handle

Reservoir
Handle

Reservoir
Cap

Water
Reservoir

OPERATING INSTRUCTIONS

1. Plug the power cord into a 120V AC electrical outlet.

2. Turn the mode knob to the High setting.

3. Turn the humidistat knob to the highest setting.

USING THE HUMIDISTAT

The humidistat feature allows you to set and maintain the humidity level

you wish for your room. The humidistat is designed to operate between

30% and 65% relative humidity range. The recommended setting 

is 40-45%. 

For BCM4505

:  To maintain 

this setting, position the

humidistat (figure 2) knob 

in the middle position. 

Turn the knob clockwise as far

as it will turn to achieve the 

highest humidistat setting. In 

this setting, the humidifier will

run constantly.

To lower your desired humidity level, simply turn the knob counter

clockwise to choose your setting.

For BCM4509:  

To take advantage of the SmartTouch™ Electronic

Humidistat, press the MODE button until the speed is set in either 

the HIGH or LOW setting, and the Desired Humidity is set.  When 

the humidity level rises above the set humidity, the humidifier will stop.  

When the humidity level drops below the set humidity, the humidifier 

will turn on automatically.

NOTE:

When the SmartTouch™ Electronic Humidistat is set, either 

the HIGH or LOW power light and the percent humidity light will remain

lit during operation.  The SmartTouch™ Humidifier has memory.  This

means that when you turn the unit back on, it will be at the last setting

the humidifier was set at.

For BCM4510:

The auto setting is designed to operate between 

30% and 65% relative humidity range. (The recommended setting 

is 40-45%.)  The auto setting may be used with any of the three 

auto speed settings (High, Medium or Low).

To program a specific humidity level in the auto setting, follow these

instructions.

1. Use the mode button to scroll to either Auto/High, Auto/Medium, 

or Auto/Low.

mode

refill

humidistat

power

Mode Knob

Control
Panel

Refill Light

Figure 2

Humidistat
Knob

Power Light

Summary of Contents for COOL MOISTURE BCM4505

Page 1: ...BCM4510 Read instructions before operating Retain for future reference Instruction Leaflet INFO LINE If after having read this leaflet you have any questions or comments on your humidifier call 1 800...

Page 2: ...ifier on a firm flat level surface 4 from wall A waterproof mat or pad is recommended for under the humidifier NEVER place it on a rug or carpet or on a finished floor that may be damaged by exposure...

Page 3: ...ifier on a firm flat level surface 4 from wall A waterproof mat or pad is recommended for under the humidifier NEVER place it on a rug or carpet or on a finished floor that may be damaged by exposure...

Page 4: ...mediately begin to empty into the base mode refill humidistat power Humidifier Housing Float underneath Moisture Outlet Control Panel Wick Filter Base Figure 1 Housing Support Handle Reservoir Handle...

Page 5: ...mediately begin to empty into the base mode refill humidistat power Humidifier Housing Float underneath Moisture Outlet Control Panel Wick Filter Base Figure 1 Housing Support Handle Reservoir Handle...

Page 6: ...m humidity level by pressing the or buttons in increments of 5 If you scroll past the maximum setting of 65 the display will automatically loop back to 30 3 Now the desired room humidity level is set...

Page 7: ...m humidity level by pressing the or buttons in increments of 5 If you scroll past the maximum setting of 65 the display will automatically loop back to 30 3 Now the desired room humidity level is set...

Page 8: ...ir with cool water replace the humidifier housing and the water reservoir Repeat Operating Instructions STORAGE INSTRUCTIONS If your humidifier will not be in use for two days or more or at the end of...

Page 9: ...ir with cool water replace the humidifier housing and the water reservoir Repeat Operating Instructions STORAGE INSTRUCTIONS If your humidifier will not be in use for two days or more or at the end of...

Page 10: ...sing warm water to refill reservoir Humidifier is reacting to room humidity level Over tightened Solution Plug in unit Check circuit breaker or outlet Refill Water reservoir Remove base and flush out...

Page 11: ...sing warm water to refill reservoir Humidifier is reacting to room humidity level Over tightened Solution Plug in unit Check circuit breaker or outlet Refill Water reservoir Remove base and flush out...

Reviews: