background image

5

3.   Remove any packaging from the new filter and 

screw it into the tank cap (F).

4.   Fill the water tank with clean water. Refit the 

filter/tank cap and replace the water tank into the 

base. 

CLEANING AND MAINTENANCE

Humidifiers provide comfort by adding moisture to 

dry, heated indoor air. To get the most benefit from 

the humidifier and to avoid product misuse, follow all 

instructions carefully, specifically the operation, care 

and maintenance guidelines. Please note this is an 

electrical appliance and requires attention when in 

use.

Cleaning your humidifier every one or two weeks, 

depending on the water conditions is important 

in order to maintain efficient, healthy, odour-free 

operation. Water quality varies widely and, combined 

with build-up of mineral scale in your humidifier, may 

under certain conditions promote the growth of micro-

organisms in the water tank.

Before cleaning, please note the following:

• 

Never immerse any part of the appliance or power 

cord and plug in water or any other liquid.

• 

DO NOT use soap, detergents, abrasives, gasoline, 

glass or furniture polish, or boiling water to clean 

any part of your humidifier. These will interfere with 

the proper operation of your unit and may affect its 

appearance.

• 

DO NOT use sharp or metal objects to clean 

mineral deposits in the reservoir. Contact with sharp 

objects can result in damage to the plastic.

• 

Mineral deposits should be soaked for up to 20 

minutes in plain vinegar and water to help with their 

removal.

• 

DO NOT clean any part of your humidifier in the 

dishwasher.

Daily maintenance

1.   Before cleaning, switch off the unit and unplug it 

from the electrical outlet.

2.   Remove the lid and lift the water tank out of you 

humidifier.

3.   Drain and rinse the base and tank thoroughly to 

remove any sediment or dirt. Wipe clean and dry 

with a clean cloth or paper towel.

4.   Refill the tank as described in the section 

Filling 

the Water Tank

. Do not over fill.

AUTO MODE

The Auto mode sets your humidifier to operate at 

a preset level of 55%. Press the Auto button (Q) to 

select the auto mode. Press the Auto button again to 

exit auto mode.

WARM MIST

The Warm mist button (P) changes the mist 

temperature from cool to warm. 

NOTE

: It can take 

approximately 30 minutes for the mist to change 

temperature. The Warm Mist button will not function if 

the unit is not producing mist.

TIMER

The timer allows your humidifer to operate for four 

pre-set times: 2, 4, 8 or 12 hours. Each press of the 

Timer button (U) will select 2, 4, 8 or 12 hours. When 

the timer is in operation, the LCD display will show 

the clock icon and the time period selected (N). 

NIGHT LIGHT

The night light (I) can be switched on or off using the 

Night light button (T).

AUTO SAFETY SHUT OFF

Your humidifier has a built in safety device When 

the water level in the water tank is low, the unit will 

beep several times and the Water tank low icon (M) 

will show. Refill the tank as described in the section 

Filling the Water Tank

. Do not overfill. The unit will  

enter standby mode after 1 minute if the water tank is 

not refilled.

WATER FILTER MAINTENANCE

The water filter is used to remove any minerals from 

the mist. The filter life is determined by the average 

daily use of your humidifier and the water hardness 

in your area. The harder the water, the greater the 

amount of minerals in the water and the more often 

you will need to replace the filter. It is strongly recom

-

mended that the filter is replaced every 2 months, 

(depending on use), or when white dust is emitted 

from your humidifier.

1.   Switch off your humidifier and disconnect it from 

the mains supply socket. Remove the lid (B) and 

lift out the water tank (C).

2.   Turn the water tank upside down and unscrew 

the filter/tank cap (Fig. 2). Unscrew the filter (E, 

Fig. 3) from the tank cap (F, Fig. 3) and dispose 

of the old filter in accordance with your local 

regulations.

Summary of Contents for BU7500

Page 1: ...pure indoor living INSTRUCTION MANUAL DIGITAL ULTRASONIC HUMIDIFIER MODEL BU7500...

Page 2: ...2 2 7L MAX A B E C D H G P Q R S T U V J K L M N O FIG 1 FIG 2 FIG 3 F I E F...

Page 3: ...ration DO NOT cover the mist outlet or place anything over it while the unit is operating Use the appliance only for its intended household use as described in this manual Any other use not recommende...

Page 4: ...HING THE UNIT ON AND OFF 1 Plug the unit into the mains supply socket 2 Press the On Off button V The LCD display H will light up white and the on off button and Auto button will light up blue 3 By de...

Page 5: ...cloth or paper towel 4 Refill the tank as described in the section Filling the Water Tank Do not over fill AUTO MODE The Auto mode sets your humidifier to operate at a preset level of 55 Press the Aut...

Page 6: ...nce no longer functions due to a design or manufacturing fault please take it back to the place of purchase with your till receipt and a copy of this guarantee The rights and benefits under this guara...

Page 7: ...e the appliance in a cool area for 12 hours Not using fresh or filtered water Wash the tank out or change the water Abnormal noise Resonance effect due to too little water in the water tank Refill the...

Page 8: ...living 2017 Jarden Consumer Solutions Europe Limited All rights reserved Imported and distributed by Jarden Consumer Solutions Europe Limited Cheadle Royal Business Park Cheadle SK8 3GQ United Kingdom...