Biolet 10 Standard Owner'S Manual Download Page 11

10 

 

Vent pipe ends at least 6” above anything within 10’ (see “Installation”)? 

 

Vent pipe unobstructed? 

 

Is the vent pipe insulated in all unconditional (i.e. attic) areas?  

 

If there is a ventilation fan in the ceiling or wall of your bathroom, do not use it. The fan will draw air from the 
bathroom, causing a back draft through the toilet. 

 

If there is a window in your bathroom and the air is drawn out through it, you should close the window. 

 

If the odor is detected during periods when there is a breeze outside. Install an approved wind directional cap 
(part# wind) that is available from BioLet or your local authorized dealer. 

Odors outside the structure 

The presence of odors outside the structure is a positive indication that the vent pipe is in an area of air turbulence 
above the roof. The vent pipe must be raised to get the top above the air turbulence. 

Excess moisture in the tray 

If you see excess moisture in the indicating tube(s) and cannot control it by adjusting the thermostat as described in 
the “Use and Care section”: 

*** IMPORTANT *** 

If liquid is present in the indicating tube on the left side of the toilet (when facing toilet), DO NOT open the 
tray door before draining off the liquid (see step 2 under “Emptying the humus tray”). This tube indicates 
there is liquid outside the tray. Removal of the door will release liquid onto the floor. 

 

Is your unit plugged in? 

 

Can you hear the fan motor running? 

 

Check for proper operation of the thermostat by turning the thermostat from 1 to 10 and listening for a slight 
“click”. 

 

Check for proper heater operation by following these steps: 

1.  Set the thermostat on 5 and run the toilet for 2 hours. 
2.  Turn the thermostat back and forth and listen very closely for a slight click. 
3.  Make a note at what setting the thermostat clicks. 
4.  Turn the thermostat to 10 and run the unit for ½ hour. 
5.  Turn the thermostat back and for to its limits again and listen for the click again. 
6.  If the click in step 5 is at a higher setting than the click in step 2, everything is working correctly. 

 

Ensure the mulch is not compacted. 

 

Ensure you are using the toilet within its limits of 3 people full-time use and 4 people part-time use. 

Excess moisture in the composting chamber 

If you notice the material inside the composting chamber is not loamy and appears to be holding excessive moisture: 

 

Is your unit plugged in? 

 

Can you hear the fan motor running? 

 

Are you mixing the material after each use? 

 

Ensure you are using approved starter mulch (see “adding starter mulch” in the “use and care” section 
above). 

 

Ensure you are adding a sufficient amount of starter mulch. 

 

Ensure there is sufficient ventilation from the toilet (see “Odors in the bathroom” above) 

 

Ensure you are using the toilet within its limits of 3 people full-time residential and 4 people part-time cabin. 

 

If all else fails add 1 quart of coarse Perlite (available from most nurseries) to each gallon of starter mulch. 

Summary of Contents for 10 Standard

Page 1: ...Rev 060802 Owner s Manual BioLet 20 Deluxe BioLet 10 Standard...

Page 2: ...atio C N 6 Use and Care 7 Precautions 7 Adding starter mulch 7 Approved mulches 7 Homemade mulch 7 Using the mixer 7 10 Standard 7 20 Deluxe 8 Adjusting the thermostat 8 Things to watch 8 Emptying the...

Page 3: ...ve you vital information about installing and maintaining your BioLet Please remember State and Local regulations always supersede instructions in this manual Always check with your local health autho...

Page 4: ...g your BioLet Check with your local health authorities and building inspector for regulations governing the installation of your BioLet Ensure there is generous air flow into the bathroom A 1 gap unde...

Page 5: ...ng coupling attached to the white 54mm pipe with no bell 10 Slide non belled black pipe into belled end of other black pipe 11 With the bell facing downward cut the black pipe so it fits the angle of...

Page 6: ...led pipe into the pipe installed in the back of the toilet Repeat until the end of the white pipe reaches the 45 elbow the last pipe in this assembly should be the pipe you cut in step 8 11 Insert the...

Page 7: ...umn early spring and winter you may find it necessary to increase the thermostat to maintain the proper operating state of a moist loamy material with no indication of liquid Conversely you may find i...

Page 8: ...f 1 quart of starter mulch per week per person Therefore one should make it a habit to add about 1 2 cup of starter material after each fecal use Approved mulches Use of only BioLet approved starter m...

Page 9: ...no liquid indicated in the tube Emptying the humus tray In a full time residential setting empty the humus tray when the compost reaches the upper mixing arm leveler or once every 6 months whichever...

Page 10: ...the surface Insect control The presence of insects in and around your BioLet is frequently an indication of excess moisture If there is excess moisture you will need to remedy this situation to be ab...

Page 11: ...unit plugged in Can you hear the fan motor running Check for proper operation of the thermostat by turning the thermostat from 1 to 10 and listening for a slight click Check for proper heater operatio...