(EN) INSTRUCTIONS FOR USE

1. PLANNING AND INSTALLATION

Install the Biolan Simplett at a level position on the floor. When 

deciding where to locate the unit, take into account the space 

required for its ventilation and liquid removal arrangements, as 

well as its use and maintenance. The unit must be placed so that 

the top cover of the tank can be opened wide enough to enable 

easy emptying.

1.1 Technical specifications

•  depth 560 mm

•  width 525 mm

•  sitting height 480 mm

•  height 515 mm

•  weight 8 kg

•  size of the inner receptacle 28 l

•  external diameter of the liquid removal pipe 32 mm

•  length of the liquid removal pipe 335 mm–935 mm

1.2 Year-round use of the toilet

If you install the Simplett toilet in a warm space, you may use it all 

year round. Then, its ventilation and liquid removal systems must 

be insulated in cold spaces, and the liquid removal pipe must be 

provided with a sufficient gradient to prevent the liquid from 

freezing in the pipe. If the liquid is collected in a canister, the can-

ister must be emptied in the autumn in order to prevent it from 

breaking due to the frost. A toilet located in a cold space can be 

used occasionally during the winter. The Simplett is manufac-

tured of frost-proof materials, so freezing does not damage it. 

1.3 Ventilation

Installing the horizontal ventilation pipe

Install the horizontal ventilation pipe (part 2) in the unit.  Observe 

that the end of the pipe must extend to above the inner recepta-

cle to enable the water, that may possibly condense, to flow into 

the inner receptacle (see Fig. 3).

Leading the ventilation pipe through the rear wall

Leading the ventilation pipe through the rear wall (Fig. 4). Make a 

lead-trough hole of at least Ø 75 mm, according to the dimension 

drawing (Fig. 1) for the horizontal ventilation pipe. The hole to be 

made in the wall must be located slightly higher than the hole in 

the unit to prevent the condensed water from remaining in the 

pipe. Cut the horizontal ventilation pipe to a suitable length so 

that the angular union used will be connected to the vertical ven-

tilation pipe with a curve as gentle as possible. Make sure that 

the pipe will be located inside the toilet as shown in Fig. 3.
Extend the horizontal ventilation pipe to above the roof ridge, us-

ing a sewer pipe of Ø 75 mm. The Ventilation Pipe Package, which 

is designed for the purpose, is available as an accessory from the 

dealers. A suitable pipe can also be obtained from HVAC stores 

and well-appointed hardware stores. We recommend using a 

rounded angular union. Any extra bends in the pipe will impede 

natural ventilation, and may cause odour problems. If you want, 

you can improve the ventilation by using the Biolan Wind Fan.

Liquids rich in nutrients must not be allowed to 

enter the soil as they cause an excessively con-

centrated nutrient load.