BIOLAN GREYWATER FILTER LIGHT User Manual Download Page 3

EN-2

FI

SV

EN

RU

Spare parts sales: in Finland dealers and the online shop at www.biolan.fi

Component list

Part

Part name

Number

Material

1

body

17722201

PE

2

top

17722202

PE

3

filter box, 5 pcs

17715050

PE

4

ventilation pipe cap, 2 pcs

18710250

PE

5

pipe 75 x 200 mm, 2 pcs

28704050

PP

6

branch sleeve 75 / 75 mm, 2 pcs

28733120

PP

7

pipe 75 x 385 mm with sleeve

28704051

PP

8

inlet pipe end

18715250

PE

9

latch

18710370

EPDM

10

washer for latch

18726140

PE

11

lead-through rubber 75 mm, black, 2 pcs

18001001

EPDM

In addition to the components illustrated in the components picture, 
the Greywater Filter light also includes:
crosshead screw M5x25 A4

20040026

RST

nut nylock M5

20020009

RST

fender washer A2 M5

20060002

RST

sealing band 12*4mm, 2,5 m

19776001

EPDM cell rubber

lifting handle

18722003

PE

plug 75 mm

18715130

PE

user manual

27722000

PAPER

Filter material

70574100

3

6

5

2

10

4

7

8

9

1

11

4

11

5

6

Component drawing

Summary of Contents for GREYWATER FILTER LIGHT

Page 1: ...GREYWATER FILTER LIGHT User manual FI SV EN RU ...

Page 2: ...or by pumping no septic tanks required The treatment capacity of one module is about 300 litres per day Content Component list 2 Component drawing 2 1 Planning and installation 3 1 1 Technical specifications 3 1 2 Location out of doors 3 1 3 Location inside a residential building 3 1 4 Air circulation 3 1 5 Conducting wastewater to the filter 4 1 6 Discharge point for the wastewater 4 1 7 Putting th...

Page 3: ...704051 PP 8 inlet pipe end 18715250 PE 9 latch 18710370 EPDM 10 washer for latch 18726140 PE 11 lead through rubber 75 mm black 2 pcs 18001001 EPDM In addition to the components illustrated in the components picture the Greywater Filter light also includes crosshead screw M5x25 A4 20040026 RST nut nylock M5 20020009 RST fender washer A2 M5 20060002 RST sealing band 12 4mm 2 5 m 19776001 EPDM cell ...

Page 4: ...l not gather even when there is flooding The filter can be installed out of doors without a cover The unit has no thermal insulation If the unit is used also in winter it must be located in a space where the temperature stays above zero at all times 1 3 Location inside a residential building If you are planning to install the filter indoors or in close prox imity to a residential building for example...

Page 5: ... sewer outlet of the house all the way to the discharge point No septic tank required The module is fitted with inlet and outlet connectors for a 75 mm sewer pipe The inlet connector is located at the upper edge of the module and the outlet connector at the lower edge It is pos sible to connect two modules in series or in parallel Serial connection The sewage pipe coming out of the building is conn...

Page 6: ...ist and the exiting water is clear and odourless and does not contain a significant amount of solid matter Check that 1 wastewater is flowing smoothly from all the openings of the box 2 the filter material has been drawn to a distance of about 5 cm from the openings in the discharge end of the box 3 the visible connections of the sewers are in order 4 the purified wastewater is flowing freely out of th...

Page 7: ... five years 1 The guarantee is valid from the date of purchase and covers possible defects in material and workmanship The guaran tee does not cover any indirect damage 2 Biolan Oy retains the right to decide about repairing or re placing damaged parts at its discretion 3 Any damage resulting from careless or forcible handling of the device from failure to observe the operating instruc tions or fro...

Page 8: ......

Reviews: