Side Rails (058-633)  

The optional side rails can be installed on both sides of the table. Each rail pivots individually to 
either the raised or lowered position. Two rails are supplied; one for each side of the table.  

To install the side rails: 
1. Using a 7/16" wrench, remove the four 1/4-20" hex head screws from under the abdominal

cushion (toward the rear of the cushion) on the side of the table to which the side rail will be
installed. Remove the strap bracket and save the screws to reinstall in step 3.

2. Position the side rail support bracket against the bottom of the cushion so the four pre-drilled

screw holes in the bracket align with the screw holes under the seat cushion.

3. Using a 7/16" wrench install the four screws removed in step 1 through the side rail support

bracket. Tighten securely.

4. Press the small piece of vinyl trim bumper onto the lower frame edge beneath the mid-point of

the seat.

5. Install the straps into the side rails strap brackets.

Using the side rails: 
1. To raise either side rail, pull out the side rail pull pin and gently swing the rail upward so that it

locks fully into position.

2. To lower either side rail, pull out the side rail pull pin and, while supporting the side rail, allow

it to gently swing down and under the table until the rail locks in place.

Figure 9.

 Installing the side rails. 

Summary of Contents for 058-702

Page 1: ...BIODEX Biodex Medical Systems Inc ECHO VASC PROTM VASCULAR ULTRASOUND TABLE OPERATION MANUAL 058 702 058 707 FN 11 308 Rev C 3 15...

Page 2: ...OUND TABLE Echo Vasc ProTM Vascular Ultrasound Table This manual covers operation procedures for the following products 058 702 Table Vascular Ultrasound Echo Vasc Pro 115 VAC 058 707 Table Vascular U...

Page 3: ...locating the Table 2 1 Height Adjustment 2 1 Trendelenburg Reverse Trendelenburg 2 1 Fowler Back Adjustment 2 2 Leveling the Table 2 2 Adjustable Sonographer Cutout Cushion 2 2 Cardiac Scanning Cutout...

Page 4: ...Carefully read these instructions prior to use Caution General Warning General Mandatory Action Dangerous Voltage On Power Off Power Earth ground Alternating Current Fuse USB Connector Cable Waste in...

Page 5: ...ie par l quipement peut tre diminu e et les r sultats pourraient tre compromis Ne quittent Jamais le patient sans surveillance sur la table Quand la table est utilis e dans un environnement mouill il...

Page 6: ...years of age 95th percentile male 20 65 years of age Product Certifications and Classifications The Echo Vasc Pro Vascular Ultrasound Table has received the following certifications and falls within t...

Page 7: ...as explained in the Before Proceeding section of this manual This product should be used only as specified in the operation manual Biodex Ultrasound Tables are designed for use in a patient environme...

Page 8: ...ssible ATTENTION Le bouchon est consid r e comme la m thode de d connexion du produit d alimentation Ne placez pas le produit dans une position o le bouchon n est pas facilement accessible CAUTION Thi...

Page 9: ...damages including loss of use sales profits or business interruption C This warranty does not apply if the product as determined by BIODEX MEDICAL SYSTEMS INC is defective due to abuse misuse modific...

Page 10: ...ime 2 After taking the information we will advise on the action we will take 3 Sometimes service personnel must consult with engineering and it may take time to get back to you Be sure to let the serv...

Page 11: ...ge from seated or standing work position Cutouts on either side of the table enable full patient access and sonographer ergonomics The cardiac scanning cutout provides open access to the patient s lef...

Page 12: ...Adjustable Sonographer Cutout Cushion 3 Hand Held Controller 4 5 Locking Swivel Casters 5 Central Floor Locking System Lever 6 Foot Support 7 Extra Wide Tabletop With 500 Lb Patient Capacity 8 Cardiac...

Page 13: ...conveniently adjusted with the hand held or optional foot controller D ring holders are provided on the end of the straps at each side of the table frame to hold the hand held controller when it is no...

Page 14: ...he handles together and lift up on the cushion until it is higher than level and then lower the cushion back down until it locks in the level position To raise the cushion lift up on the cushion There...

Page 15: ...oot support can be removed from the table completely NOTE The foot support cannot be stowed beneath the table when the table is in Reverse Trendelenburg 15 Doing so can cause damage to both the foot s...

Page 16: ...etop push it forward as it slides completely underneath the tabletop 6 The foot support will rest beneath the table securely in place Return Foot Support Platform To Tabletop Position 1 Grab the top e...

Page 17: ...est utilis e dans un environnement mouill il est recommand que le contr leur de pied soit couvert avec un sac de plastique et cachet si inattaquable que possible To install the foot controller 1 Locat...

Page 18: ...board pivot is adjustable at any point along its 130 arc To adjust press the yellow button on the arm board and move to the desired location release yellow button See Figures 5 8 To remove the arm bo...

Page 19: ...gainst the bottom of the cushion so the four pre drilled screw holes in the bracket align with the screw holes under the seat cushion 3 Using a 7 16 wrench install the four screws removed in step 1 th...

Page 20: ...The optional headrest is removable and adjustable To install the headrest simply slide it into the receiving tube at the head end of the table until it clicks into place Figure 10 The optional headre...

Page 21: ...t and tighten to secure the paper dispenser bracket in place 5 Repeat steps 1 4 for the opposite side 6 Place a role of paper on the paper dispenser rod and install the rod between the brackets Press...

Page 22: ...e support bracket against the side frame so the two pre drilled screw holes in the bracket align with the screw holes on the tabletop frame The I V pole should face up and toward the head end of the t...

Page 23: ...hyde Upholstery Color Graphite Motions Height Adjustable 23 to 39 58 4 to 99 cm Trendelenburg 0 to 15 Reverse Trendelenburg 0 to 30 Fowler Back 0 to 80 infinitely adjustable Controls Hand Control Acti...

Page 24: ...B 1 ECHO VASC PRO VASCULAR ULTRASOUND TABLE Appendix B Specifications...

Page 25: ...BIODEX MEDICAL SYSTEMS INC 2015 B 2...

Page 26: ...B 3 ECHO VASC PRO VASCULAR ULTRASOUND TABLE...

Page 27: ...BIODEX MEDICAL SYSTEMS INC 2015 B 4...

Page 28: ...C 1 ECHO VASC PRO VASCULAR ULTRASOUND TABLE APPENDIX C PARTS AND ASSEMBLY ILLUSTRATIONS...

Page 29: ...BIODEX MEDICAL SYSTEMS INC 2015 C 2...

Page 30: ...C 3 ECHO VASC PRO VASCULAR ULTRASOUND TABLE...

Page 31: ...BIODEX MEDICAL SYSTEMS INC 2015 C 4...

Page 32: ...C 5 ECHO VASC PRO VASCULAR ULTRASOUND TABLE...

Page 33: ...BIODEX MEDICAL SYSTEMS INC 2015 C 6...

Page 34: ...C 7 ECHO VASC PRO VASCULAR ULTRASOUND TABLE...

Page 35: ...BIODEX MEDICAL SYSTEMS INC 2015 C 8...

Reviews: