4. Read the result.
The measurement result will be done in
3 seconds.
The reading is shown together with green
LED and three short beeps.
●
The body of the thermometer is not water-resistant.
Never put the thermometer under a running tap or submerge it into
water. Use a soft and dry cloth to clean it. Do not use abrasive
leaners.
●
Store the thermometer in a cool and dry location. Free from dust and
away from direct sunlight.
Remove the battery
The thermometer comes with two 1.5 V AAA alkaline batteries. The
meter will display “ ” to alert you when the meter power is getting
low, please follow the steps below to replace new batteries
immediately.
1. Remove the battery cover as the arrow
direction accordingly.
2. Remove the old batteries and replace
with two 1.5V AAA size alkaline batteries.
Positive ( + ) and Negative ( - ) are displayed
on the back of battery cover.
3. Close the battery cover.
NOTE :
1. Although the thermometer works when " " appears,we still
recommend that you change the batteries to obtain an accurate
result.
2. Remove the batteries if stored for a long period of time.
3. The batteries should be kept away out of child’s reach. If they are
swallowed, promptly see a doctor for help.
METER MEMORY
Recalling the Memory
Your thermometer stores 20 most recent
readings
1. Be sure the thermometer is OFF before
recalling this memory.
2. Press Memory Button to enter the
memory mode.
Each time you press the Memory Button, a
result will be displayed
in the order of dates (latest result
shown first), together with ” ”
and number ( from 1 to 20 ).
LED in green or red will appear according
to the memory reading.
When the memory is full, the oldest result is
deleted as the new one added. When the
last record displayed in the Display, press
Memory Button again to return the first
record.
3. Exit the memory.
Press Set Button to exit the memory or
keep the meter in idle for 10 seconds to
switch off automatically.
MAINTENANCE
Care & Cleaning
●
The probe is not waterproof. Please wipe with a clean and dry
cotton swab to clean the probe on the inside.
SYSTEM TROUBLESHOOTING
Measurement Result
Troubleshooting
The table below shows problems you may encounter. All error
messages below would be shown together with backlight. Please
follow "what to do" to resolve problems. If the problem still exists,
please call your local dealer for help.
SPECIFICATIONS
Model No.: 1265
Dimension & Weight : 151.5 x 55 x 41 mm, 74g (includebatteries)
Power Source : 2 x 1.5 V AAA alkaline batteries
Displayed temperature range :
Forehead : 32°C to 43°C (89.6°F to 109.4°F)
Object : 0°C to 100°C (32°F to 212°F)
Display resolution: 0.1 °F/0.1°C
Accuracy :
FOR BODY MODE:
±0.2°C (±0.36°F) from 36.0°C (96.8°F) to 39.0°C (102.2°F)
±0.3°C (±0.54°F) from 32.0°C (89.6°F) to 35.9°C
(96.6°F) and from 39.1°C (102.4°F) to 43.0°C ( 109.4°F)
FOR OBJECT MODE : ± 1°C (±2°F) from 0°C (32°F) to 100°C (212°F)
Temperature unit : °C or °F
Operating temperature range : 16°C to 40°C (60.8°F to 104°F)
Operating humidity : 95% RH or less
Storage temperature range : -25°C to 55°C (-13°F to 131°F)
Storage humidity : 95% RH or less
Memory capacity : 20 measurements
Expected service life : 3 years
DISPOSAL
Adhere to the applicable regulations when disposing of the device.This product must not be disposed of
together with domestic waste.All users are obliged to hand in all electrical or electronic devices, regardless
of whether or not they contain toxic substances, at a municipal or commercial collection point so that they
can be disposed of in an environmentally acceptable manner.
Please remove the batteries before disposing of the device/unit. Do not dispose of old batteries with your
household waste, but at a battery collection station at a recycling site or in a shop.
REFERENCE STANDARDS
Device Standard :
Device Corresponds to the requirements of the
standard for infrared thermometers
ASTM E1965-98
EN 12470-5
EN 60601-1-2 : 2007/AC:2010
Electromagnetic Compatibility : Device fulfills the stipulations of the standard EN 60601-1-2
The stipulations of EU-Directive 93/42/EEC for Medical Devices Class Ila have been fulfilled.
SYMBOL INFORMATION
DETAILED INFORMATION
About Normal Body Temperature & Fever
The temperature in the forehead and temple area differs from the
internal temperature, which is taken orally or rectally. Vasoconstriction,
an effect which constricts the blood vessels and cools the skin, can
occur during the early stages of a fever. In this case, the temperature
measured by the Biocare Forehead Thermometer may be unusually low.
If the measurement therefore does not match the patient’s own
perception or is unusually low, repeat the measurement every 15
minutes. As a reference, you can also measure the internal body
temperature using a conventional oral or rectal thermometer.
Body temperature can vary from one individual/person to next. It also
varies by location on the body and time of day. Below shows the
statistical normal ranges from different sites. Please keep in mind that
temperatures measured from different sites, even at the same time,
should not be directly compared. Fever indicates that the body
temperature is higher than normal. This symptom may be caused by
infection, overdressing or immunization. Some people may not
experience fever even when they are ill. These include, but are not
limited to, infants younger than 3 months old, persons with compro-
mised immune systems, persons taking antibiotics, steroids or
antipyretics (aspirin, ibuprofen, acetaminophen), or persons with
certain chronic illnesses. Please consult your physician when you feel ill
even if you do not have fever.
Table*
1
Body Site Normal Temperature Range
*
1
. Body Temperature at WebMD; website: http://firstaid.web
d.com/body-temperature retrieved at 2010 Jan 7.
0.6°C (1°F) or more above or below
37°C (98.6°F)
0.3°C to 0.6°C (0.5°F to 1°F) higher
than oral temperature
0.3°C to 0.6°C (0.5°F to 1°F) lower
than oral temperature
Oral
Rectal/ear
Axillary(armpit)
Measured temperature falls outside
the displayed temperature range of
32°C to 43°C (89.6°F to 109.4°F), is
shown on the display with red LED.
●
Hi-temperature ≥43°C (109.4°F)
●
Lo-temperature < 32°C (89.6°F)
Measured temperature falls in
normal reading, within the range
of 32°C to 37.5°C (89.6°F to 99.5°F),
is shown on the display with green
LED.
Measured temperature falls in
fever reading, ≥37.5°C (99.5°F) and
< 43°C (109.4°F), is shown on the
display with red LED.
Appear when
environmental
temperature is
below system
operation range.
Put the thermometer
under operating
temperature range of
16°C to 40°C(60.8°F
to 104°F)
MESSAGE
WHAT IT MEANS
MESSAGE
WHAT IT MEANS
WHAT TO DO
Appear when
environmental
temperature is
above system
operation range.
Battery is low
and " " appears
on display.
Put the thermometer
under operating
temperature range of
16°C to 40°C(60.8°F
to 104°F)
Please replace
batteries as
soon as possible.
If the thermometer
is broken or
affected by EMF.
Please contact
the customer
service line.
MESSAGE
SYMBOL
REFERENT
WHAT IT MEANS
WHAT TO DO
Read instructions before use
Manufacturer
Serial number
CE mark
Authorized representative in the European Community
Caution, consult accompanying documents
Type BF Equipment
Collection for electrical and electronic equipment
Shanghai International Trading Corp.
GmbH(Hamburg)
Eiffestrasse 80, 20537 Hamburg, Germany
TEL:+49‐40‐2513175
FAX:+49‐40‐255726
Biocare Asia Co., LTD
No.260,Mayun Road, New District Suzhou,
Jiangsu,215129,P.R.C
TEL:+86‐512‐68091772
FAX:+86‐512‐68097761
www.bca-medical.com
EN 60601-1-4 :1996
EN 60601-1-6 : 2010