PROCEDURE TO REPLACE THE LAMP, THE QUARTZ SLEEVE AND THE
SEAL
Ø
These operations must be carried out in case of:
•
Replacement of the lamp, quartz sleeve or seal
•
Checking/cleaning of the quartz sleeve
•
Alarm on the PRO3 monitor (option)
1
The reactor MUST be SWITCHED OFF, ISOLATED, DRAINED, UNCLIPPED
and INSTALLED VERTICALLY
2
Unscrew the gland to release the lamp cable
remove the reactor cover
3
Dismount the lamp connector.
4
Remove the reactor from its support by making it slide through the clips.
5
Make sure that the UV lamp is cooled enough before handle it.
6
Remove the lamp (use the connector if necessary) and lay it on a clean and
smooth surface.
Carry out this operation carefully
without touching the glass of the lamp
with the hands
Do not let the lamp fall into the quartz sleeve, it could break off into
the quartz sleeve and damage the quartz
7
Unscrew the stainless steel nut.
Remove the flat washer.
8
Remove carefully the quartz sleeve :
Insert a thumb or finger in the sleeve and withdraw it gently until the seal
comes free from its housing, while remaining well aligned with the axis.
9
Take hold of the quartz sleeve and extract it fully, making sure that you
keep it ABSOLUTELY well aligned with the axis.