BIO RAD DTE4027 User Manual Download Page 7

DTE4027 RFID Reader Module 

User Manual 

 

  
 

1  INTRODUCTION 

 
 

1.1  General Description 

 
The Bio-Rad DTE4027 module is a complete read and write solution for 13.56 MHz Mifare Classic cards 
(1k, 4k). 
It  is  designed  to  be  integrated  in  an  equipment  in  order  to  add  RFID  feature  with  low  engineering  and 
certification efforts. 
 
 

2  SPECIFICATIONS 

 
 

2.1  Physical Specifications 

 

2.1.1 

Dimensions 

 
 

Width: 

70 mm 

 

Height: 

40 mm 

 

2.1.2 

Weight 

 
 

Board alone: 

10 g 

 
 

2.2  Technical Specifications 

 

2.2.1 

General Specifications 

 
 

Power Input Requirements: 

5VDC +/- 10 % regulated 

 

Power Consumption: 

150 mA maximum 

 

Operating Environment 

 

Temperature: 

-20 to + 50°C 

 

Humidity: 

20 - 80% non-condensing 

                       Storage Conditions 
 

Temperature: 

-40 to + 85°C 

 

Humidity: 

10 - 95% 

 

Operating frequency: 

13.56 MHz 

 

Protocol: 

Mifare 13.56 MHz 

 

Transmission range: 

5 to 15 mm 

 

Number of write cycles: 

>15,000 

 

Communication protocol 

Compliant with ISO 14443A 

 

Communication interface: 

UART, TTL levels 

 

Data rate: 

9600 bps, 8 bits, 1 stop, no parity 

 

Maxim number of simultaneous 

 

modules

1

 

48 

 
 
                                                    

1

 Number of modules in the same host and being active together at the same time 

Summary of Contents for DTE4027

Page 1: ...User Manual DTE4027 RFID Reader Module REF DTE4027 February 2014...

Page 2: ...fications 6 2 1 1 Dimensions 6 2 1 2 Weight 6 2 2 Technical Specifications 6 2 2 1 General Specifications 6 3 SYSTEM DESCRIPTION 7 3 1 Electrical Interface 7 3 2 Block Diagram 7 3 3 Mechanical Drawing...

Page 3: ...h and familiarize yourself with the contents of the user manual ABOUT THIS MANUAL This manual is intended for design engineers and technicians The following topics are included Principles of Operation...

Page 4: ...ient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connect...

Page 5: ...unction with any other antenna or transmitter Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux condi...

Page 6: ...both intentional and unintentional emission requirements We recommend that the minimum 20cm separation distance for people antennas transmitter should be mentioned in the end product documentation Th...

Page 7: ...Technical Specifications 2 2 1 General Specifications Power Input Requirements 5VDC 10 regulated Power Consumption 150 mA maximum Operating Environment Temperature 20 to 50 C Humidity 20 80 non conden...

Page 8: ...e read via UART On the back of the RFID board there is a push button micro switch that is connected to two spare inputs on the slave processor RA2 and RA3 This can be read via the UART communication 3...

Page 9: ...DTE4027 RFID Reader Module User Manual 8 3 3 Mechanical Drawing 77 mm Antenna Centre 27 5 mm 27 5 mm 56 5 mm LED 5 1 mm 1 6 mm 3 5 mm 3 0 mm SW With its plastic enclosure...

Page 10: ...s must be W rth Elektronik P N 7427114 4 2 Installation Install the board with screws using the four holes The PCB should be covered by an RF permissive material cover e g plastic Power the board with...

Reviews: