Bio-Optica BEC150 Instructions For Use Manual Download Page 1

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 

 

Instructions for use

 

 

BEC150

 

 

 

Paraffin embedding station

 

In vitro diagnostic - medical device 

 

 

 

 

 

CND code: W0202059002 

 

Bio-Optica code: 40-200-002 
Reference number code: 1831667  
 
 
Always keep this manual near the instrument.  
Read thoroughly before operating this instrument. 

Summary of Contents for BEC150

Page 1: ...raffin embedding station In vitro diagnostic medical device CND code W0202059002 Bio Optica code 40 200 002 Reference number code 1831667 Always keep this manual near the instrument Read thoroughly be...

Page 2: ...ica Milano S p A Via San Faustino 58 20134 Milan Phone 39 02 21 27 13 1 Fax Italy 39 02 21 53 000 Fax Export 39 02 21 54 155 www bio optica it info bio optica it claims bio optica it 2 Publication dat...

Page 3: ...ructions or specific information provided in this manual Instructions drawings illustrations and any other technical or general information in this user manual are not binding with regard to our produ...

Page 4: ...1 2 SYMBOLS AND THEIR MEANING 6 1 3 PROPER USE 7 1 4 USER GROUP 7 1 5 TYPE OF INSTRUMENT 7 1 6 SAFETY WARNINGS 8 1 7 DANGER WARNINGS 8 2 DESCRIPTION 9 2 1 MAIN COMPONENTS 9 2 2 MAIN CHARACTERISTICS 10...

Page 5: ...02 21271310 6 The electrical safety of this instrument is ensured only when it is correctly connected to an efficient grounding system as required by current electrical safety standards It is necessa...

Page 6: ...20 Rev 00 1 2 SYMBOLS AND THEIR MEANING Symbol for CATALOG NUMBER Symbol for SERIAL NUMBER Symbol for ALTERNATING CURRENT Symbol for FUSE Symbol for CONSULT THE INSTRUCTIONS FOR USE Symbol for CE MARK...

Page 7: ...he required temperature Fill the molds containing the tissue samples with paraffin Heat and maintain the temperatures of the embedding cassettes with samples and molds Set and manage temperatures sepa...

Page 8: ...er use and in a state of perfect technical safety Faults that can compromise safety must be eliminated immediately 1 7 DANGER WARNINGS The safety devices supplied on this instrument by the manufacture...

Page 9: ...x Export 39 02 21 54 155 www bio optica it info bio optica it claims bio optica it 9 Publication date 02 03 2020 Rev 00 2 DESCRIPTION 2 1 MAIN COMPONENTS 1 Tank 2 Display 3 On off button 4 Flow adjust...

Page 10: ...e consistently kept at a proper temperature so as to ensure the constant maintenance of the desired working temperature Dimensional characteristics Dimensions WxDxH 560 x 605 x 405 mm Paraffin tank ca...

Page 11: ...display Detection of paraffin level via integrated level sensors Detection of presence of paraffin collection cassettes by means of presence sensors so as to increase workplace safety Heated and remo...

Page 12: ...e instrument grip it only at the lower base of the housing at the front or rear and pull it out Installation Place the instrument on a flat and stable work bench and connect it to the power outlet 230...

Page 13: ...a it claims bio optica it 13 Publication date 02 03 2020 Rev 00 4 USE 4 1 INSTRUMENT PARTS Paraffin tank 1 The paraffin tank has a capacity of 4 liters The paraffin temperature can be adjusted between...

Page 14: ...h the blue knob 8 located above the nozzle Workspace 3 The temperature of the work area can be adjusted between 55 C and 75 C it includes the embedding area the forceps holder 5 and the cold spot 4 A...

Page 15: ...facilitate work for ambidextrous operators or to work with forceps and pestle at the same time Trays for molds or cassettes 12 Depending on the preferred working direction the two heated trays can be...

Page 16: ...n it will be in stand by mode The control panel provides an overview of the machine s operating status The upper part shows a machine status bar where the date and time the programmed activities and a...

Page 17: ...k with relative level Temperature of the side thermal units Temperature of the work plate Status of the Peltier cell On off WARNING The temperatures are visible only when the machine is heating up The...

Page 18: ...ica it claims bio optica it 18 Publication date 02 03 2020 Rev 00 5 2 SETTINGS MENU The settings menu allows adjusting the machine s operating conditions as well as allowing a log of operating warning...

Page 19: ...kday Note To correctly set the weekly switch on and off programming see corresponding chapter first set the correct time and date 1 Weekday selection select the current weekday 2 Set the current time...

Page 20: ...kground no work session has been set The machine will remain in stand by 2 Details of the work sessions set it is possible to display the times of the various work sessions By clicking on the day box...

Page 21: ...1 PELTIER ON OFF Peltier cell on off enables manually controlling the switching on and off of the desired temperature 2 BOOST enables speeding up the heating phase of the main tank 3 LED work light in...

Page 22: ...t claims bio optica it 22 Publication date 02 03 2020 Rev 00 5 6 TEMPERATURE SETTINGS In this screen by moving the temperature slider it is possible to adjust the operating temperatures of the units P...

Page 23: ...ent in the most suitable way for his her work The Operator Panel menu allows enabling or disabling some functions in the instrument This section is accessible to all technicians and allows them to cus...

Page 24: ...ca Milano S p A Via San Faustino 58 20134 Milan Phone 39 02 21 27 13 1 Fax Italy 39 02 21 53 000 Fax Export 39 02 21 54 155 www bio optica it info bio optica it claims bio optica it 24 Publication dat...

Page 25: ...only of histological samples fixed and embedded in paraffin Maintenance Periodic annual maintenance must be carried out by qualified personnel authorized by Bio Optica For information please contact...

Page 26: ...e parafina BEC150 Della classe Of class Der klasse De la classe De la clase Altro dispositivo Other device Sonstiges Produkt Autre dispositif Otro dispositivo Soddisfa tutte le disposizioni della Dire...