Bio-Optica 40-300-203 User Manual Download Page 3

 

    

 

 

     

 

 

      

User Manual

 

             

 

 

 

Bio-Optica Milano S.p.A. Via San Faustino 58 - 20134 Milano  

Phone +39 02.21.27.13.1 - Fax 39 02.21.53.000 - Fax 39 02.21.54.155 

www.bio-optica.it

 – 

[email protected]

 – 

[email protected]

 

 

 

3

 

Edited: 19/02/2021 

Rev. 03 

 

IMPORTANT NOTE

 

 
The information, figures, notes and estimates in this 
documentation represent the most advanced stage of 
science and technology and are the result of in-depth 
research.  
We are not obliged to update this manual regularly in 
response to new technical developments, or send revised 
versions, updates, etc. for this manual to our clientele.  
We accept no liability for any errors in data, notes, 
technical illustrations etc. in this manual, in line with 
current Italian legislation. In particular, we are not liable in 
any way for any damage to property or other indirect 
damage arising from failure to comply with instructions or 
specific information provided in this manual.  
Instructions, drawings, illustrations and any other 
technical or general information in this user manual are 
not binding with regard to our products. 

 
The provisions of the contract agreed between our 
company and the customer prevail in all cases.  
Bio-Optica reserves the right to make changes to 
technical specifications or the production process without 
notice. This is necessary to allow constant progress in 
production and technology.  
This document is protected by copyright. All copyright is 
held by Bio-Optica S.p.A.  
Even partial reproduction of the text or illustrations by 
printing, photocopying, microfilm, Web Cam or other 
methods  -  including all electronic instruments and 
systems  -  is only permitted with the prior written 
authorization of Bio-Optica S.p.A.  
The serial number and year of manufacture are provided 
on the nameplate affixed to the rear of the device. 

 
 
 
 

 
 
 

Published by:  
Bio-Optica S.p.A. 
Via San Faustino, 58  
20134 Milan  
Italy  
 
Telephone (+39) 02-2127131 
Fax: (+39) 02-2153000 
Internet: [email protected]  

 
 
 
 
 

Summary of Contents for 40-300-203

Page 1: ...imit dell apparecchio Leggere attentamente prima della messa in funzione User Manual BCP230 Cooling Plate In vitro diagnostic medical device Bio Optica code 40 300 203 Always keep this manual near the...

Page 2: ...Optica Milano S p A Via San Faustino 58 20134 Milano Phone 39 02 21 27 13 1 Fax Italia 39 02 21 53 000 Fax Export 39 02 21 54 155 www bio optica it info bio optica it claims bio optica it 2 Edited 19...

Page 3: ...ions or specific information provided in this manual Instructions drawings illustrations and any other technical or general information in this user manual are not binding with regard to our products...

Page 4: ...it 4 Edited 19 02 2021 Rev 03 TABLE OF CONTENTS TABLE OF CONTENTS 4 1 IMPORTANT INFORMATION 5 1 1 PRECAUTIONS FOR USE 5 1 2 SYMBOLS AND THEIR MEANING 6 1 3 PROPER USE 7 1 4 USER GROUP 7 1 5 TYPE OF I...

Page 5: ...71310 6 The electrical safety of this instrument is ensured only when it is correctly connected to an efficient grounding system as required by current electrical safety standards It is necessary to c...

Page 6: ...ev 03 1 2 SYMBOLS AND THEIR MEANING Symbol for CATALOG NUMBER Symbol for SERIAL NUMBER Symbol for ALTERNATING CURRENT Symbol for FUSE Symbol for CONSULT THE INSTRUCTIONS FOR USE Symbol for CE MARKING...

Page 7: ...eeze and keep the molds in which the fabric samples were placed with paraffin This sturdy and ergonomic modular system guarantees a linear and customizable workflow and offers comfort and ease of use...

Page 8: ...jury for the user or third parties or damage to the device or other property The instrument is intended only for proper use and in a state of perfect technical safety Faults that can compromise safety...

Page 9: ...1 Cooling zone 2 Wrist Rest 3 Power button 4 Glass cover Painted sheet steel chassis Large stainless steel surface that offers space for storage of up to 300 paraffin blocks placed in vertical positio...

Page 10: ...DxH 410 x 605 x 405 mm Cooling surface dimensions WxD 370 x 350 mm Weight 24 Kg Power connections Power supply 230V 50 60Hz Power 600 Watt Fuses N 2 fuses of 6 3 Ampere 5x20 mm T6 3AH250V Other connec...

Page 11: ...strument grip it only at the lower base of the housing at the front or rear and pull it out Installation Place the instrument on a flat and stable work bench and connect it to the power outlet 230V 50...

Page 12: ...y of histological samples fixed and embedded in paraffin Maintenance Periodic annual maintenance must be carried out by qualified personnel authorized by Bio Optica For information please contact the...

Page 13: ...Optica Milano S p A Via San Faustino 58 20134 Milano Phone 39 02 21 27 13 1 Fax Italia 39 02 21 53 000 Fax Export 39 02 21 54 155 www bio optica it info bio optica it claims bio optica it 13 Edited 19...

Page 14: ...asse Of class Der klasse De la classe De la clase Altro dispositivo Other device Sonstiges Produkt Autre dispositif Otro dispositivo Soddisfa tutte le disposizioni della Direttiva 98 79 CE relative ai...

Page 15: ...Optica Milano S p A Via San Faustino 58 20134 Milano Phone 39 02 21 27 13 1 Fax Italia 39 02 21 53 000 Fax Export 39 02 21 54 155 www bio optica it info bio optica it claims bio optica it 15 Edited 19...