BIO-LAB CANADA Pool Pilot Soft Touch 36 Installation And Operation Manual Download Page 3

Section 1b

 – GENERAL PRODUCT INFORMATION 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

READ AND FOLLOW ALL INSTRUCTIONS

 

 

INSTALLATION AND EQUIPMENT RELATED  

 

Installation of all MINERAL SPRINGS 

Pool Pilot

™ Soft Touch models: 

 

When installing and using your 

Pool Pilot

™ 

Soft Touch

 Control Box, basic safety precautions must always be 

followed, including the following: 
 

1.  Follow all aspects of the local and National Electrical Code(s) when installing your Control Box. 

 

2.  During installation, mount your Control Box to ensure the least amount of direct exposure to rain, garden sprinkler water, direct 

sunlight or any corrosive environment. 

 

3. 

DANGER – Risk of electrical shock.  Install Control Box at least 3 m (10ft.) for 115VAC Units, from the inside wall of the 

pool or spa using non-metallic plumbing.  1.5 m (5ft.)  minimum distance for 230VAC Units. 

 
4. 

All field-installed metal components such as rails, ladders, drains or similar hardware within 3 m (10ft.) of the spa or hot tub 
shall be bonded to the equipment grounding bus with copper conductors not smaller than 8.4 mm² (No. 8 AWG) in the U.S.A. 
and 6.3mm² (No. 6 AWG) in Canada.

 

 

5.   

WARNING – Maintain water chemistry in accordance with manufacturer’s instructions. 

 

6. 

DANGER – To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all 

times.  Children should not use spas, hot tubs or pools without permanent adult supervision. 

 
 

Equipment Related  

 

115/230VAC, 50/60 Hz Models (fixed wiring) 

 

A wire connector is provided on your 

Pool Pilot

™ 

Soft Touch

 to connect a minimum 8.4 mm² (No. 8 AWG) in the U.S.A. and 

6.3mm² (No.6 AWG) in Canada. solid copper bonding conductor between this unit and any metal equipment, metal enclosures of 
electrical equipment, metal water pipe or conduit within 1.5 m (5ft.) of the unit. 

 

A bonding terminal is located inside your 

Pool Pilot

™ 

Soft Touch

.  To reduce the risk of electrical shock, this terminal must be 

connected to the grounding means provided in the electrical supply panel with a continuous copper wire equivalent size to the 
circuit conductors supplying your 

Pool Pilot

™ 

Soft Touch

 

A disconnection device from the power source, with a contact separation of at least 3mm (0.12 in.) in all poles, must be 
incorporated in the fixed wiring for permanently wired units. 
 

The input voltage to the 

Pool Pilot

™ 

Soft Touch

 must match the 115/230VAC, 50/60 Hz jumper terminals on the Circuit board, 

marked “TRANSFORMER PRIMARY”, shown on Page 5. 

 

 
 
 
 

SAVE THESE INSTRUCTIONS

 
 

2

Summary of Contents for Pool Pilot Soft Touch 36

Page 1: ...acteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE IMPORTANT NSF50 C READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This...

Page 2: ...________________ Control Unit Control Unit Model Number ST36______________ Serial Number ____________________________ Cell Model Number RC 5 Serial Number ____________________________ Customer Assista...

Page 3: ...ry in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not u...

Page 4: ...Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Req...

Page 5: ...Remove the cover by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the s...

Page 6: ...r Yel Br Bl 2 pin ORP Cell Cord AC Line In Plug Plug 1 6 5 4 3 2 Connector Connectors Pool Pilot AC Line IN CONTROL BOX BASE PLATE AC LINE IN Wiring diagram also located on inside of cover For 230 VAC...

Page 7: ...ify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equi...

Page 8: ...water chemistry parameters monthly and compare to the Saturation Index WARNING Changing the Reversing cycle to SHORT will also reduce cell life However operating the cell under scaled conditions on N...

Page 9: ...urities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR...

Page 10: ...dium hypochlorite and does not affect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name a...

Page 11: ...rol Circuit lift off metal cover electrical connections remove these board removes with cover fuses and pump aux relay Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 Control Panel C...

Page 12: ...mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use a non fuming pre mixed cell cleaner per label directio...

Page 13: ...dered separately Red Cap Plug for RC 5 cell cord 19050 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Cell RC 5 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union...

Page 14: ...Cell B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive...

Page 15: ...e of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 The second v...

Page 16: ...AD THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Imported to Canada for BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 REGISTRATION NO 28048 PEST CONTROL PRODUCTS AC...

Page 17: ...GISTRATION NUMBER 28048 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine gen...

Page 18: ...ormation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accura...

Reviews: