Field
Description
•
(default value): The type of service is ignored.
•
-% &0 E+3
: Differentiated Services Code Point
according to RFC 3260 is used to signal the priority of IP
packets (indicated in binary format, 6 bit).
•
-% -*+ E+3
: Differentiated Services Code Point
according to RFC 3260 is used to signal the priority of IP
packets (indicated in decimal format).
•
-% >6*+ E+3
: Differentiated Services Code
Point according to RFC 3260 is used to signal the priority of
IP packets (indicated in hexadecimal format).
•
): &0 E+3
: The TOS value is specified in binary
format, e.g. 00111111.
•
): -*+ E+3
: The TOS value is specified in decimal
format, e.g. 63.
•
): >6*+ E+3
: The TOS value is specified in
hexadecimal format, e.g. 3F.
COS Filter
(802.1p/Layer 2)
Enter the service class of the IP packets (Class of Service,
CoS).
Possible values are whole numbers between
and
(
.
The default value is
.
11.6.2 Rule Chains
Rules for IP filters are configured in the Rule Chains menu. These can be created separ-
ately or incorporated in rule chains.
In the Networking->Access Rules->Rule Chains menu, all created filter rules are listed.
11.6.2.1 Edit or New
Choose the
icon to edit existing entries. To configure access lists, select the New but-
ton.
The Networking->Access Rules->Rule Chains->New menu consists of the following
fields:
Fields in the Basic Parameters menu.
11 Networking
bintec elmeg GmbH
190
be.IP 4isdn