DESCRIPTION

This regulator has been designed to receive air at main 
line pressure and to deliver it at a desired lower regulated 
pressure. 

SPECIFICATIONS

  Air inlet 

3/8" NPT(f)

  Air outlets (2 regulated) 

1/4" NPT(f) (1 Ea.)

   

3/8" NPT(f) (1 Ea.)

  Air outlets (2 unregulated)  1/4" NPT(f) (2 Ea.)
  Air Capacity 

60 CFM

  Maximum Temp. 

150° F

  Max. Inlet Pressure 

150 psi

  Regulator range 

0-125 psi

INSTALLATION

1.  Maximum inlet pressure and operating temperature 

ratings are 150 psig and 150° F (intermittent  to 180° F).

2.  Install as close as possible to where regulated air is 

needed.

3.  Install the unit with the air flowing through the body in 

the direction indicated by the arrow.

4.  Install the same pipe size unit as the pipe line in use.  

Avoid using fittings, couplings, etc., that restrict the air 
flow, unless maximum flow is not needed.

5.  Regulator may be installed so that adjusting handle is in 

any position. Attach gauge to one 1/4" female port.

6.  Turning the adjusting screw clockwise increases the 

regulated pressure and turning it counterclockwise 
reduces the regulated pressure.

REGULATOR MAINTENANCE

1.  Occasionally remove bottom plug (7) and clean valve 

seat (10) and body (5). Clean parts with denatured 
alcohol, wipe off seat and blow out body with 
compressed air.  

2.  To disassemble regulator, remove screws, bonnet, spring 

and spring button. Diaphragm assembly can now be 
removed.

3.  Check all o-rings for signs of damage. Replace if 

necessary.

4.  Reassembly parts. Insert stem of valve through hole in 

regulator body. Install spring and o-rings. Screw bottom 
plug into body.

BINKS MODEL HAR-511 AIR REGULATOR

NOTE

Erratic operation or loss of regulation is usually due to dirt in 

the valve area and cleaning is necessary. If cleaning does not 

correct the problem, replace the items included in Repair Kit 

KK-4977. (See diagram below.)

If unit leaks air at “A”,  

install Repair Kit KK-4977.

A

HAR-511 BOTTOM VIEW

3/8" NPT(f)

Regulated Port

1/4" NPT(f)

Unregulated Port

3/8" NPT(f)

Inlet

1/4" NPT(f)

Regulated Port

1/4" NPT(f)

Outlet

Unregulated

EN

77-2781-R9  (2/2018)

3 / 4

www.carlisleft.com

Summary of Contents for HAR-511

Page 1: ...wise specified by the manufacturer this product is specifically designed for compressed air service and use with any other fluid liquid or gas is a misapplication For example use with or injection of certain hazardous gases in the system such as oxygen or liquid pertroleum gas could be harmful to the unit or result in a combustible condition that may cause fire or explosion Manufacturer s warranti...

Page 2: ...pment instruction manual NOISE HAZARD You may be injured by loud noise Hearing protection may be required when using this equipment STATIC CHARGE Fluid may develop a static charge that must be dissipated through proper grounding of the equipment objects to be sprayed and all other electrically conductive objects in the dispensing area Improper grounding or sparks can cause a hazardous condition an...

Page 3: ... Turning the adjusting screw clockwise increases the regulated pressure and turning it counterclockwise reduces the regulated pressure REGULATOR MAINTENANCE 1 Occasionally remove bottom plug 7 and clean valve seat 10 and body 5 Clean parts with denatured alcohol wipe off seat and blow out body with compressed air 2 To disassemble regulator remove screws bonnet spring and spring button Diaphragm as...

Page 4: ...tions Region Industrial Automotive Automotive Refinishing Americas Tel 1 800 992 4657 Tel 1 800 445 3988 Fax 1 888 246 5732 Fax 1 800 445 6643 Europe Africa Middle East India Tel 44 0 1202 571 111 Fax 44 0 1202 573 488 China Tel 8621 3373 0108 Fax 8621 3373 0308 Japan Tel 81 45 785 6421 Fax 81 45 785 6517 Australia Tel 61 0 2 8525 7555 Fax 61 0 2 8525 7575 Carlisle Fluid Technologies is a global l...

Reviews: