2
Operation Manual
460 Automatic Spraygun
Important
Read and follow all instructions and Safety Precautions before using this
equipment
Description
A lightweight automatic spray gun for small work suitable for use with most solvent based coating materials.
The design features a single air supply to operate the single acting cylinder and provide the atomizing air. A
remotely positioned two way control valve (supplied by user) triggers the gun. Coating material supply is by a
pressure feed system.
IMPORTANT
: These guns are not designed for use with highly corrosive or highly abrasive coating material
and if used with such materials it must be expected that the need for thorough cleaning and/or the necessity
for replacement parts will be increased. If there is any doubt regarding the suitability of a specific material,
advise what material is to be used and/or submit a sample for test.
MODELS
The automatic spray gun type Binks 460 complies with ATEX regulations
94/9/EC
,
protection level II 2 G X
T6 suitable for use in Zones 1 & 2.
Gun Ref
Tip size
Tip model
Tip reference
Needle Ref
Air Cap model
Air cap ref
103010 0.75
mm J930SS 200361 180086 J92P 200833
103013 1.0
mm J940SS 200362 180380 J92R 200834
103019 1.5
mm K960SS 200363 180087 K92P 200838
103027 1.0
mm J940SS 200362 180086 J92P 200833
103058 0.75
mm J930SS 200361 180086 J92R 200834
103062 1.0
mm J940SS 200362 180086 J92S 200831
103081 0.5
mm J920SS 200360 180086 J92P 200833
EC Declaration of Conformity
We,
Finishing Brands UK Limited, Ringwood Rd, Bournemouth, Dorset, BH11 9LH, UK
, as the manufacturer of the
Spray gun model 460
, declare, under our sole responsibility that the equipment to which this document relates is in
conformity with the following standards or other normative documents:
BS EN 292-1 PARTS 1 & 2: 1991, BS EN 1953: 1999;
and thereby conform to the protection requirements of
Council Directive
98/37/EEC
relating to
Machinery Safety Directive,
and;
EN
13463-1:2001,
council Directive
94/9/EC
relating to
Equipment and Protective Systems intended for use
in Potentially Explosive Atmospheres protection level II 2 G X
.
D. Smith
, General Manager
30th January 2013
Finishing Brands UK Limited reserves the right to modify equipment specification without prior notice.