Binks 43P6370-0000-6 Manual Download Page 2

2

  

Warning

!

In this part sheet, the words 

WARninG

cAUtion

 and 

note

 are used to emphasize important safety information as follows:

 CAution

Hazards or unsafe practices which could 

result in minor personal injury, product 

or property damage.

!

   WARninG

Hazards or unsafe practices which could 

result in severe personal injury, death or 

substantial property damage.

!

notE

important installation, operation or 

maintenance information.

Read the following warnings before using this equipment.

ReAd tHe MAnUAl 
Before operating finishing equipment, read and 
understand all safety, operation and maintenance 
information provided in the operation manual.

PReSSURe Relief PRocedURe 
always follow the pressure relief procedure in the 
equipment instruction manual.

MedicAl AleRt
any injury caused by high pressure liquid can be 
serious. If you are injured or even suspect an injury:
  a)  go to an emergency room immediately.
  b)  tell the doctor you suspect an injection injury.
  c)  Show the doctor this medical information or 

the medical alert card provided with your 
airless spray equipment.

  d)  tell the doctor what kind of fluid you were 

spraying or dispensing.

  e)  Refer to the Material Safety Data Sheet for 

specific information.

toxic flUid & fUMeS 
Hazardous fluid or toxic fumes can cause serious 
injury or death if splashed in the eyes or on the skin, 
inhaled, injected or swallowed. leaRN and kNoW 
the specific hazards or the fluids you are using.

WeAR ReSPiRAtoR 
toxic fumes can cause serious injury or death if 
inhaled. Wear a respirator  as recommended by 
the fluid and solvent manufacturer’s Material 
Safety Data Sheet.

electRic SHock / GRoUndinG 
Improper grounding or sparks can cause a 
hazardous condition and result in fire, explosion 
or electric shock and other serious injury.

PRojectile HAzARd
you may be injured by venting liquids or gases 
that are released under pressure, or flying debris.

fiRe And exPloSion HAzARd
Improper equipment grounding, poor ventilation, 
open flame or sparks can cause hazardous 
conditions and result in fire or explosion and 
serious injury.

StAtic cHARGe 
fluid may develop a static charge that must be 
dissipated through proper grounding of the 
equipment, objects to be sprayed and all other 
electrically conductive objects in the dispensing 
area. Improper grounding or sparks can cause a 
hazardous condition and result in fire, explosion 
or electric shock and other serious injury.

WeAR SAfety GlASSeS 
failure to wear safety glasses with side shields 
could result in serious eye injury or blindness.

oPeRAtoR tRAininG 
all personnel must be trained before operating 
finishing equipment.

eqUiPMent MiSUSe HAzARd 
equipment misuse can cause the equip ment to 
rupture, malfunction, or start unexpectedly and 
result in serious injury.

keeP eqUiPMent GUARdS in PlAce 
Do not operate the equipment if the safety 
devices have been removed.

HiGH PReSSURe conSideRAtion
High pressure can cause serious injury. Relieve all 
pressure before servicing. Spray from the spray 
gun, hose leaks, or ruptured components can 
inject fluid into your body and cause extremely 
serious injury.

Get iMMediAte MedicAl Attention
to prevent contact with the fluid, please note the 
following:
  a)  Never point the gun/valve at anyone or any 

part of the body.

  b)  Never put  hand or fingers over the spray tip.
  c)  Never attempt to stop or deflect fluid leaks 

with your hand, body, glove or rag.

  d)  always have the tip guard on the spray gun 

before spraying.

  e)  always ensure that the gun trigger safety 

operates before spraying.

  f)  always lock the gun trigger safety when you 

stop spraying.

de-eneRGize, dePReSSURize, diSconnect  
And lock oUt All PoWeR SoURceS dURinG 
MAintenAnce
failure to De-energize, disconnect and lock out 
all power supplies before performing equipment 
maintenance could cause serious injury or death.

foR fURtHeR SAfety infoRMAtion ReGARdinG BinkS And deVilBiSS eqUiPMent,  

See tHe GeneRAl eqUiPMent SAfety Booklet (77-5300).

it iS tHe ReSPonSiBility of tHe eMPloyeR to PRoVide tHiS infoRMAtion to tHe oPeRAtoR of tHe eqUiPMent.

cA PRoP

65

PRoP 65 WARninG
WaRNINg: this product contains chemicals known 
to the State of california to cause cancer and 
birth defects or other reproductive harm.

Summary of Contents for 43P6370-0000-6

Page 1: ...d impingement orifices in conjunction with applied fluid pressures Impingement orifices usually are matched but may be dissimilar to balance divergent viscosities and or ratios The 18 8 stainless steel head is designed with cross drilled ports for ease of maintenance The ports allow access to remove impacted cured resins Immersion in solvent will not affect the PTFE seals Both resin 1 4 NPS ports ...

Page 2: ...ous conditions and result in fire or explosion and serious injury Static Charge Fluid may develop a static charge that must be dissipated through proper grounding of the equipment objects to be sprayed and all other electrically conductive objects in the dispensing area Improper grounding or sparks can cause a hazardous condition and result in fire explosion or electric shock and other serious inj...

Page 3: ...s of time such as lunch overnight or weekends the fol lowing procedures are recommended A Remove items 1 2 3 and 4 and place in clean sol vent Pack mixing chamber with petroleum jelly B Leave gun connected to the hoses and formulator and shut off fluid supply to the gun but do not bleed the pressure For long shut down periods it is necessary to purge flush the system completely use solvent recomme...

Page 4: ... 1719 stem 1 32 102 1704 Bushing 1 33 102 3335 gasket 2 34 102 1749 plunger 1 35 52 487 nut 2 36 102 2066 yoke 1 37 102 2067 block 1 38 102 2069 stop 1 39 20 3553 Ball 1 40 84 353 Spring 1 41 102 2065 Safety lock yoke assembly 1 42 102 1709 Trigger 1 44 102 1757 Valve Assembly 2 45 102 1756 packing 2 46 102 1725 retainer 2 47 102 1730 spring 2 48 102 1726 gland 2 49 54 1663 nut 2 50 102 1759 needl...

Page 5: ... care not to damage wire i Tighten gland 48 into retainer 46 j Wrap retainer 46 threads with PTFE tape and insert into head 8 Reinstall needle assembly 50 by revers ing above procedures a to c in Step C 2 3 The seat 9 is designed for long life and is not usually removed for normal maintenance If it is damaged and must be removed repeat procedures a to c Step C 2 then a Remove plug 5 b Insert 3 16 ...

Page 6: ...6 NOTES ...

Page 7: ...NOTES 7 ...

Page 8: ...237 5000 Toll Free Customer Service and Technical Support 800 992 4657 Toll Free Fax 888 246 5732 Binks Sales and Service www binks com WARRANTY This product is covered by Binks 1 Year Limited Warranty 77 1722R 12 Revisions PTFE reference update throughout P1 Corrected model number P2 Added Prop 65 warning P8 Updated contact information ...