BINDICATOR
®
Installation, Operation & Maintenance Manual
4
6.0 Technical Specifications
Function:
Level, distance and volume measurement of liquids and solids.
Measuring Range:
Flexible probe: to 78ft
Deadband: Top: 15.8in Dieletric < 10
11.8in Dieletric > 10
Deadband: Bottom: 14.25in
Counter Weight Diameter.: 1.575in; length 10.25in
(Weight is tapped with 1/2" - 13 to allow tethering or anchoring)
Accuracy:
+/-
0.6in
Repeatability:
0.04in
Dielectric Constant:
>
2.3
Probe Materials:
Flexible cable 316SS
Operating Pressure:
232
psi
Flange Temperature:
-22° to 194°F
Electronics Temperature:
-22° to 131°F
Connection:
1.5"
MNPT
Protection Category:
IP66; Nema 4X
Power Supply:
24VDC (18 to 35VDC)
Output:
4/20mA current loop into max. of 750 Ohms
Communication:
HART protocol
Approvals:
CE
Weight
:
Without probe 4.4lbs (2Kgs)
Materials of
Construction:
Housing: Aluminium with white epoxy coating
Cable and Weight: 316 SS
Gaskets: Buna N
Electrical Connection
M16 CONNECTOR
Terminals:
Max wire size 16AWG (1.5mm)
Cable Entries:
1 x M16 x 1.5 (with standard cable gland: cable
clamping area =0.137 - 0.315in(3.5-8mm)).
Electrical Signal Output
Electrical Connection:
Two
wire
Power Supply:
18 to 35 VDC
Current Output:
4/20mA
Environment
Ambient Temperature:
-22° to 131°F
Protection Category to
EN 60529 / IEC 529:
IP66, Nema 4X