background image

BINDICATOR

®  

        

Installation, Operation & Maintenance Manual   

                         

4

6.0 Technical Specifications

Function:

 

Level, distance and volume measurement of liquids and solids.

Measuring Range:

 

Flexible probe:   to 78ft 

  

Deadband:    Top: 15.8in Dieletric < 10

  

  

                   11.8in Dieletric > 10

  

Deadband: Bottom: 14.25in

  

Counter Weight Diameter.:  1.575in; length 10.25in

  

(Weight is tapped with 1/2" - 13 to allow tethering or anchoring)

Accuracy:

 +/- 

0.6in 

 

Repeatability:

 0.04in

 

Dielectric Constant:

 > 

2.3

  

Probe Materials:

 

Flexible cable 316SS

Operating Pressure:

 

232 

psi 

   

Flange Temperature:

  

-22° to 194°F 

  

 

Electronics Temperature:

 -22° to 131°F    

 

Connection:

 1.5" 

MNPT 

 

 

Protection Category:

  

IP66; Nema 4X

  

  

 

 

Power Supply:

  

24VDC (18 to 35VDC)

Output:

 

4/20mA current loop into max. of 750 Ohms

  

Communication:

  

HART protocol  

Approvals:

  

CE 

  

  

 

 

 

Weight

:  

Without probe 4.4lbs (2Kgs)

  

  

 

Materials of 
Construction:

 

Housing: Aluminium with white epoxy coating    

 

 

 

 

 

  

Cable and Weight:  316 SS

  

Gaskets: Buna N

Electrical Connection

 

  

 

 

 

M16 CONNECTOR

Terminals:

 

Max wire size 16AWG (1.5mm) 

Cable Entries:

 

1 x M16 x 1.5 (with standard cable gland: cable 

  

clamping area =0.137 - 0.315in(3.5-8mm)).

  

Electrical Signal Output

Electrical Connection:

 Two 

wire

Power Supply:

 

18 to 35 VDC

 

Current Output:

  

4/20mA 

Environment

Ambient Temperature:

  -22° to 131°F  

 

 

 

 

Protection Category to
EN 60529 / IEC 529: 

 

IP66, Nema 4X

Summary of Contents for TDR-1000

Page 1: ...TDR180002 Rev B INSTALLATION OPERATION MAINTENANCE MANUAL TDR 1000 GUIDED WAVE RADAR Quick Start Guide...

Page 2: ...model is not installed correctly or used in approved applications dangers may arise such as product overflow Ensure that all personnel installing wiring and calibrating this device are suitably quali...

Page 3: ...asured Variable distance level volume 3 1 Measuring Range 1 4 0 Mounting 4 1 Excessive Bending of the Cable 2 4 2 Mounting on a Nozzle 2 4 3 Interference between two TDR s 2 5 0 Electrical Connection...

Page 4: ...Measured variable distance level volume The primary measured variable is the distance between the tank mounting flange and a reflecting surface surface of the product measured The output represents t...

Page 5: ...le BE CAREFUL NOT TO BEND OR KINK CABLES TOO MUCH 4 2 Mounting on a nozzle 4 3 Interference between two TDR 1000 Avoid nozzle size higher than 5 9 especially when B 3 1 Try to ensure A does not exceed...

Page 6: ...ng No shielding needed Power supply 1 Remove the screw P and lift off the connector from the signal converter 2 Put a screwdriver in F and separate N from R 3 Connect the current loop to terminal 1 an...

Page 7: ...194 F Electronics Temperature 22 to 131 F Connection 1 5 MNPT Protection Category IP66 Nema 4X Power Supply 24VDC 18 to 35VDC Output 4 20mA current loop into max of 750 Ohms Communication HART protoc...

Page 8: ...t 1 1 6 Probe length 1 2 4 Length unit 1 2 6 1 Unit name 1 2 6 2 Unit factor 1 2 5 Volume unit 1 3 1 Current output function 1 3 2 Current output range error 1 3 3 Min scale for current 1 3 4 Max scal...

Page 9: ...BINDICATOR Installation Operation Maintenance Manual 6 Notes...

Page 10: ...NTURE BOULEVARD SPARTANBURG SC 29306 PHONE 864 574 8060 FAX 864 574 8063 CUSTOMER CARE 800 778 9242 WWW BINDICATOR COM SALES BINDICATOR COM 2007 ALL RIGHTS RESERVED ALL DATA SUBJECT TO CHANGE TDR18000...

Reviews: