4.2 Charge the rechargeable battery

 

Charge the rechargeable battery directly by insert the charger into the charging jack. The LED is red during the charging 

process; the LED will turn green when the battery is full.   

 

 

 

 

 

 

 

 

 

Charge the rechargeable battery box directly 

 

 

 

 

 

 

Charge the rechargeable battery box on the instrument 

 

Note

 

a) Please charge the rechargeable battery when the battery is empty. That could extend the battery service life. 

b) Please charge the rechargeable battery every 2-3 months since the instrument leaving factory. 

 

4.3 Instrument placement   

a) Place the instrument on the platform directly 

 

 

 

 

 

 

 

 

 

b)

 

Install the instrument on the tripod by the 5/8’’ screw thread 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LS533H

Page 1: ...out of range Slope scanning function could set the grade value for the axis accurately TILT mode has the unleveled alarm function the laser head stop rotating to insure the construction accuracy when...

Page 2: ...he marked polarity direction and install the battery box to the instrument Install the alkaline battery box b Mount the rechargeable battery box onto the instrument directly Install the rechargeable b...

Page 3: ...argeable battery box directly Charge the rechargeable battery box on the instrument Note a Please charge the rechargeable battery when the battery is empty That could extend the battery service life b...

Page 4: ...t the grade value will display as 00 000 f After powering on the instrument if there is the remote control work with it the status of remote controlling status will display if there is no remote contr...

Page 5: ...e instrument vibrated then TILT will be touched off The laser head will stop rotating to flash TILT symbol on the display flash quickly instrument will not self level again e When the TILT mode is tou...

Page 6: ...found beyond tolerance please make adjustment according to methods as follows 5 1 X Y axis accuracy test a Put a table 20m far away from the wall indoors and place the instrument on the table with th...

Page 7: ...on coefficient of the axis would be around 1600 2495 if the accuracy could not meet with requirement after calibration within this range please contact the service center or distributor for service b...

Page 8: ...onal disassembly will result in the damage of instrument Keep the cleanness of instrument especially the laser output window and remove dust by the gentle operation of soft clean cloth Take the batter...