Binary B-540-EXT-230-RS Installation Manual Download Page 2

2

IMPORTANT SAFETY INSTRUCTIONS 

To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this 
manual. Keep this manual for future reference.

1.  Do not expose this apparatus to rain or moisture. Do not expose this equipment to dripping 

or splashing, and ensure that no objects filled with liquids, such as vases, are placed on the 
equipment. Do not use this apparatus near water.

2.  Do not remove cover. No user serviceable parts inside. 

3.  Clean only with a dry cloth.

4.  Do not block any ventilation openings. Install according to manufacturer’s instructions.

5.  Do not install near any heat sources such as radiators, heat registers, stoves or other 

apparatus (including amplifiers) that produce heat.

6.  Do not override the safety purpose of the polarized or grounding plug. A polarized plug has 

two blades, one of which is wider than the other. A grounding plug has two matching blades 
and a third grounding prong. The wide blade or the third prong is provided for your safety. If 
the provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.

7.  Protect the power cord from being walked on or pinched, particularly at the plug end and 

where the power cord is attached to the apparatus.

8.  Only use attachments and accessories specified by the manufacturer.

9.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus 

has been damaged in any way, such as when the power supply cord or plug is damaged, 
liquid has been spilled on or objects have fallen into the apparatus, the apparatus has 
been exposed to rain or moisture, the apparatus does not operate normally, or it has been 
dropped.

10. To completely disconnect this equipment from power, disconnect the power supply cord 

from the power outlet.

The lightning flash with arrowhead symbol, within 
an equilateral triangle, is intended to alert the user 
to the presence of uninsulated dangerous voltage 
within the product’s enclosure that may be of 
sufficient magnitude to constitute a risk of electric 
shock to persons.
The exclamation point within an equilateral 
triangle is intended to alert the user to the 
presence of important operating and maintenance 
(servicing) instructions in the literature 
accompanying the appliance.

CAUTION

CAUTION: TO REDUCE THE RISK OF 

ELECTRICAL SHOCK.

DO NOT REMOVE COVER. NO USER 

SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED 

SERVICE PERSONNEL.

Summary of Contents for B-540-EXT-230-RS

Page 1: ...Source Mute 2ch HDMI Out Audio INSTALLATION MANUAL HDBaseT EXTENDER B 540 EXT 230 RS...

Page 2: ...let 7 Protect the power cord from being walked on or pinched particularly at the plug end and where the power cord is attached to the apparatus 8 Only use attachments and accessories specified by the...

Page 3: ...pplications 8 6 1 HDBaseT Link RJ45 Connection 8 6 2 IR Control Connections 9 6 2 1 Point to Point IR Receiver Stereo 3 5mm Receiver Only 10 6 2 2 IR Control In Mono 3 5mm Transmitter Only 10 6 2 3 IR...

Page 4: ...le with HDMI 2 0 and HDCP 2 2 products The Power over Cable PoC feature enables the extender to be powered from either end 2 FEATURES Extends all HDMI formats up to Cable Type Cat 5e 6 Cat 6a 7 1080i...

Page 5: ...t D IR Flasher Out IR output for connection to IR Flasher E IR Control In Connect to the IR output of a control system or IR connecting block to send IR signals to the remote location Does not supply...

Page 6: ...onnect to the HDMI input of a sink display D IR Flasher IR output to connect to IR Flasher E IR Receiver IR input to connect to IR Receiver or to output of a control system F DIP Switches DCE DTE Sele...

Page 7: ...upply to the thread locking power connector unless PoC is being used to send power from the receiver DO NOT plug the power supply into an AC outlet until Receiver Installation is completed 5 2 B 540 E...

Page 8: ...Link RJ45 Connection This device is specified to operate with category cables for communication between the transmitter and receiver The transmission path may include a maximum of two keystones and t...

Page 9: ...uts PLAY 24VDC1A INPUT PWR HDMI OUT 24VDC1A INPUT PWR Control In HDMI IN RS 232 LINK DTE DCE ON SERVICE 5 3 2 HDBaseT 1 2 ON RS 232 LINK ON SERVICE 5 3 2 HDBaseT DTE DCE 1 2 ON HDTV RS 232 LINK DTE DC...

Page 10: ...6 2 2 IR Control In Mono 3 5mm Transmitter Only The IR Control IN port is used to send a wired IR signal from an IR Flasher connected to the Receiver This connection does not include power for an IR...

Page 11: ...3 1 HDBaseT Link category See Section 6 1 FIGURE 9 RS 232 Connections 6 3 1 RS 232 Control DB 9 Connection Bidirectional RS 232 signals are transmitted between the B 540 EXT 230 RS Transmitter and Rec...

Page 12: ...e necessary to modify the firmware in the B 540 EXT 230 RS To perform firmware updates the dipswitches must be set to DTE Down and Service Detailed instructions and updated firmware will be posted to...

Page 13: ...Signal Bidirectional Carrier frequency 20 60kHz Connections HDBaseT Link 1x RJ45 1x RJ45 HDMI 1x HDMI Type A 19 pin female 1x HDMI Type A 19 pin female IR Receiver In 1x 3 5mm Stereo IR Control In 1...

Page 14: ...y This warranty includes parts and labor repairs on all components found to be defective in material or workmanship under normal conditions of use This warranty shall not apply to products that have b...

Page 15: ...15...

Page 16: ...Rev 160414 1120 2016 Binary...

Reviews: