Warning: the device is equipped with a safety system which prevents operation if the convection
heater is not in a vertical position.
First use
Warning: run the appliance for at least a few hours to eliminate the "new smell" and any oil residue
from the manufacturing process. During this operation ventilate the room well to eliminate the "new
smell" that is given off.
To use the heater, proceed as follows:
•
Before inserting the plug into the power outlet to verify that the switch is in pos. "0".
•
Insert the plug into the socket.
•
Turn the switch in position "I" and you will hear a beep, the display lights up and shows the
temperature (TEM) and the recently set temperature (SET). The device is in standby mode,
and if you do not select any buttons, after about one minute, the display turns off.
•
Press "
" to activate the resistance 800W and 800W the display (warm low power); Press "
" once to activate 1200W (heat comfortable), a second time if you want to 2000W
(instant hot).
•
To activate the timer, press the "" button.
•
If desired, press the "", to operate the fan and a second time to turn it off.
•
To operate the heater to adjust the temperature "SET" more than room "TEMP". To adjust
the temperature, press the "+" or "-" until the desired value; the resistance is activated only
when the ambient temperature is lower than set.
•
To turn off the unit press “
” , switch in pos.0, and remove the plug from the plug point.
If the device is not in use for long periods of time, remove the plug from the plug point.
Description
Model with switch (type S601.EU)
The heater is equipped with the following adjustment:
- Switch (A) located on the side to turn on the fan (turbo), turn on () or off (
●
)
• Switch (B) to adjust the three powers: 0 / 800W / 1200W / 2000W.
Furthermore, the appliance is equipped with a switch that stops the rollover operation in case of a fall.
Reposition it vertically, you activate standby.
USE
Before each use, ensure that the appliance is in good working order, and that the power cable is not
damaged: if the cable is damaged, it must be replaced by the manufacturer or its service centre or by
someone with a similar qualification in order to prevent any risks. Ensure the air inlet and the heating
element are free of dust, lint, or anything similar: this improves the heater's performance, and prevents
overheating. Check for these conditions periodically.
Warning: before assembling, disassembling and cleaning the device, make sure it is disconnected
from the mains.
Warning: the device is equipped with a safety system which prevents operation if the convection
heater is not in a vertical position.
First use
Warning: run the appliance for at least a few hours to eliminate the "new smell" and any oil residue
from the manufacturing process. During this operation ventilate the room well to eliminate the "new
smell" that is given off.
15
/
41
Assembly page 15/41