FORCE
TM
602V/X BLOWER Owner’s Manual
Part No 441502
441502_A_HI
7
MAINTENANCE
PERIODIC
MAINTENANCE
Periodic maintenance should be performed at the following intervals:
Maintenance Operation
Every Use
Daily or Every 5 Hours
Every 100-150 Hours
Inspect for worn or damaged parts
Check for excessive vibration
Inspect impeller for cracks or damage
Inspect for loose parts
IMPELLER REMOVAL
1. Wait for engine to cool and disconnect spark plug.
2. Remove housing front cover by removing the ten screws from around outside of front cover and the exhaust knob (item
#22) and nut (item #14).
3. Remove impeller bolt (item #29), lock washer (item #7) and washer (item #28).
4. DO NOT pry on impeller. Pull on center hub area only of impeller. If impeller slides off freely, proceed to (step 6).
5. If the impeller does not loosen, use a pry bar against the back of the hub and the plate and apply pressure to separate
the impeller from the shaft.
DO NOT
use the pry bar to apply pressure to any plastic part such as the impeller or the
main housing. Using a penetrating oil can help loosen a stuck impeller.
6. Reinstall new impeller in reverse order of removal.
7. Tighten impeller bolt. Torque impeller bolt (see Parts List on page 10 for proper impeller bolt torque specifications).
TIRE AIR PRESSURE
Check at regular intervals and maintain.
Rear Tires - 20 Psi (137 kPa).
NOT
FOR
REPRODUCTION