29
www.bigbananatools.com
appendix (a) contd.
PS100 OBDII/CAN OBDII
O2S W.R.
B2,S3
Bank 2 – Sensor 3 (wide range O2S) Oxygen Sensor Current
O2S W.R.
EQ_RAT24 Bank 2 – Sensor 4 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R. B2,S4
Bank 2 – Sensor 4 (wide range O2S) Oxygen Sensor Current
O2S W.R.
EQ_RAT11
Bank 1 – Sensor 1 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R. B1,S1 Bank 1 – Sensor 1 (wide range O2S) Oxygen Sensor Current
O2S W.R.
EQ_RAT12 Bank 1 – Sensor 2 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R. B1,S2
Bank 1 – Sensor 2 (wide range O2S) Oxygen Sensor Current
O2S W.R. EQ_RAT21 Bank 2 – Sensor 1 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R. B2,S1 Bank 2 – Sensor 1 (wide range O2S) Oxygen Sensor Current
O2S W.R. EQ_RAT22 Bank 2 – Sensor 2 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R. B2,S2
Bank 2 – Sensor 2 (wide range O2S) Oxygen Sensor Current
O2S W.R EQ_RAT31 Bank 3 – Sensor 1 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R B3,S1
Bank 3 – Sensor 1 (wide range O2S) Oxygen Sensor Current
O2S W.R. EQ_RAT32 Bank 3 – Sensor 2 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R.
B3,S2
Bank 3 – Sensor 2 (wide range O2S) Oxygen Sensor Current
O2S W.R.
EQ_RAT41 Bank 4 – Sensor 1 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R. B4,S1
Bank 4 – Sensor 1 (wide range O2S) Oxygen Sensor Current
O2S W.R. EQ_RAT42 Bank 4 – Sensor 2 (wide range O2S) Equivalence Ratio (lambda)
O2S W.R.
B4,S2
Bank 4 – Sensor 2 (wide range O2S) Oxygen Sensor Current
APPENDIX B
This applies to ISO 9141-2, SAE J1850, and ISO 14230-4
definition for service $06.
TID(TEST ID SCALING DESCRIPTION)
$01 Rich to lean sensor threshold voltage (constant)
$02 Lean to rich sensor threshold voltage (constant)
$03 Low sensor voltage for switch time calculation (constant)
$04 High sensor voltage for switch time calculation (constant)
$05 Rich to lean sensor switch time (calculated)
$06 Lean to rich sensor switch time (calculated)
$07 Minimum sensor voltage for test cycle (calculated)
$08 Maximum sensor voltage for test cycle (calculated)
$09 Time between sensor transitions (calculated)
$0A Sensor period (calculated)
$0B-$1F reserved - to be specified by SAE and/or ISO
$21-$2F manufacturer Test ID description
$30-$3F manufacturer Test ID description
$41-$4F manufacturer Test ID description
$50-$5F manufacturer Test ID description
$61-$6F manufacturer Test ID description
$70-$7F manufacturer Test ID description
$81-$9F manufacturer Test ID description
www.Xtooltech.com