WWW.BIGASSLIGHT.COM © 2017 DELTA T CORP. ALL RIGHTS RESERVED.
5
PREVENTIVE MAINTENANCE
CAUTION: Do not clean the fixture, especially the lens, with scouring
pads. Overexposure to certain chemicals such as toluene, acetone,
ethyl acetate, or ethylene dicholoride could cause damage.
Clean the light bar periodically with a damp cloth. Methanol, ammonia, and
n-hexane-based cleaners can be used on the lens without risk of damage.
TROUBLESHOOTING
If the ambient temperature is 113°F (45°C) or above, Light Bar may not
operate due to its electronics safety protection.
If Light Bar is not working, make sure:
• Battery is fully engaged with Light Bar and the locking ring locked.
• Light Bar is within its normal operational temperature range of -4 °F to
113 °F (-20 °C to 45 °C).
• Light Bar buttons are operational (you should feel a slight recoil after
pressing).
If the battery is not charging when placed in the charging station, make
sure:
• The outlet is receiving power.
• The battery is fully inserted into the charging station.
• The charger is operational (check with another battery if possible).
• The battery and charger are not in a location where the temperature is
below 32 °F (0 °C) or above 113 °F (45 °C), or the battery will not charge.
In case of damage to a lens, contact 1-877-244-3267 for a replacement.
!